Nighthawk KN-COEG-3 manual Part One - Your Nighthawk CO and Gas Alarm, Nighthawk’s Unique Features

Models: KN-COEG-3

1 25
Download 25 pages 38.34 Kb
Page 6
Image 6
Nighthawk’s Unique Features

Part One – Your Nighthawk CO and Gas Alarm

Nighthawk’s Unique Features

Digital Display

The continuous digital display shows you the level of carbon monoxide (if any) the unit is sensing as well as if Gas is present. The unit updates this reading every 15 seconds so you can watch levels rise or fall.

Note: If the unit does not sense any CO or gas, the reading is zero (0). In most homes, the unit reads “0” all the time. A reading of “0” is expected under normal conditions, and is good. The blinking dot after the number shows you the unit is operating.

Test/Reset Button

This button has three functions. First, this is the button you press when you test the unit monthly (see page 1-5 for further details). Secondly, you press this button if the unit alarms and you want to silence the alarm. This will reset the unit and it will then again start monitoring for CO or Gas, if CO concentration is above 70 ppm the alarm will again sound within 6 minutes. It’s also used when resetting the peak level memory. (See page 1-7).

Peak Level Button

By pressing this button, you can see the peak CO level recorded by the alarm since it was last cleared or unplugged. This Nighthawk fea- ture allows you (or heating contractor or fireman) to see exactly how big a CO problem you have so you can react accordingly. (More on the peak level memory feature on page 1-7).

Sensors

The CO sensor is a highly sensitive, electrochemical sensor that is CO- specific to help avoid false alarms. Turn to page 1-7 for more information on how to care for and protect the alarm.

The Gas sensor is a metal oxide sensor designed to detect natural gas (methane) or propane.

Sounder Alarm

This is the loud 85 decibel pulsing alarm that will sound to alert you to a potential problem. Alarm condition for CO is 4 quick beeps – fol- lowed by 5 seconds of silence – followed by 4 quick beeps. Repeat with a number showing in the display (CO concentration in PPM). The alarm pattern for Gas is a 1/2 second alarm on, 1/2 second of silence - repeating with “GAS” shown in the display.

Caution: Continuous exposure to this sound level at close range over an extended period of time may cause hearing loss. We recommend you cover the sounder with your finger while testing. More on testing on page 1-5,6.

Keyholes

When the alarm is mounted to the wall, these keyholes slide onto the screws in the wall. (See “How to install your alarm on page 1-4).

Pull-Out Transformer/Adapter

This unique Nighthawk feature enables the alarm to be used as a direct plug unit, a wall mounted unit or a table top unit. More on how this unique feature is used for different application, page 1-4.

9V Backup Battery

This CO and Gas alarm is not battery operated. The 9V battery is to supply a short-term backup during a power outage. In the event of a power outage, a fully charged 9V battery will continue operating the CO alarm for at least 20 hours, unless Gas is detected during battery backup conditions. This will significantly shorten the bat- tery life.

What Carbon Monoxide and Explosive Gas Alarms Can and Cannot Do

This unit is designed to sense unacceptable levels of CO or Gas from malfunctioning furnaces, appliances, Gas engines or other sources.

This unit will provide early warning of the presence of carbon monoxide, usually before a healthy adult would experience symp- toms. It will provide warning of a Gas condition before 25% of the LEL for methane or propane is detected.

This early warning is possible, however, only if your Nighthawk CO and Gas alarm is located, installed and maintained as described in this user’s guide.

When on AC power, this unit is designed to act as a continuous mon- itor, it is not designed for use as a short-term testing device to per- form a quick check for the presence of CO or Gas.

Alarms have limitations. Like any other electronic device, CO and Gas alarms are not fool-proof.

CO and Gas alarms have a limited operational life. You must test your CO and Gas alarm monthly, because it could fail to operate at any time. If your CO and Gas alarm fails to test properly, or if its self-diag- nostic test reveals a malfunction, immediately have the unit replaced. See back page for warranty information.

CO and Gas alarms can only sense CO that reaches the unit’s sensor. Carbon monoxide may be present in other areas without reaching the alarm. The rate at which CO reaches the unit may be affected by doors or other obstructions. In addition, fresh air from a vent or open window or any other source may prevent CO from reaching the sen- sor. Please observe cautions on page

1-3 “Where to install your alarm.”

CO or Gas could be present on one level of the home and not reach the alarm installed on a different level. For example, CO or Gas in the basement may not reach an alarm on the second level, near the bedrooms. For this reason, we recommend you provide complete coverage by placing a CO and Gas alarm on every level of the home.

This unit is not a smoke alarm. It will not sense smoke or fire. For early warning of fire you must install smoke alarms, even though car- bon monoxide can be generated by a fire.

CO and Gas alarms are not a substitute for property, disability, life or other insurance of any kind. Appropriate insurance coverage is your responsibility. Consult your insurance agent.

Your CO/Gas alarm is not designed to continually detect explosive gas while on battery only operation. The CO/Gas alarm is provided with a 9 volt battery backup for short term protection against the presence of carbon monoxide or explosive gas. For the first four min- utes after the unit goes into battery backup operation, the explosive gas sensor will operate as if on AC power. However, after four min- utes, to extened battery life, the unit will go into battery conserve mode and will only sample for explosive gas once every eight min- utes. Explosive gas could be present during this 8-minute period without the unit going into alarm.

1-2

Page 6
Image 6
Nighthawk KN-COEG-3 Part One - Your Nighthawk CO and Gas Alarm, Nighthawk’s Unique Features, Digital Display, Sensors