![](/images/new-backgrounds/1230959/23095927x1.webp)
I N F R A R E D M A I N S Y S T E M U N I T
STATUS
IN
Figure 7
12 Volt Trigger Output
The Niles MSU480 provides a 12VDC output that can be trig- gered one of two ways:
1.The presence of status voltage on the
2.Discrete infrared on and off commands.
The discrete on and off commands are available for download at: www.nilesaudio.com/techsupport. This output can be used to trigger any device that requires 12VDC to be activated. Examples include:
•Dropping a motorized screen
•Activating a television lift
•Turning on a voltage controlled switching device (e.g.: Niles
Installation
Simply plug a cable with a 3.5mm plug (tip=positive, sleeve=ground) into the jack labeled “12VDC/200mA OUT- PUT”. Connect the other end of the cable to the device that will be triggered or activated (Figure 7).
13