CHANGING OR CLEANING OF THE BRUSH

CHANGING OR CLEANING OF THE BRUSH

 

 

 

 

 

1.

Unplug the power cord from the electrical outlet.

 

 

 

 

 

2.

Release the brush roller by unlocking the bearing

 

 

 

 

 

 

block. Push the button backwards left towards the

 

 

 

 

 

 

unlocking symbol at the brush housing.

 

 

 

 

 

3.

Grasp at the bearing block and pull it out from the

 

 

 

 

 

 

brush housing.

2

 

3

 

4.

Remove the used brush.

 

 

 

 

 

5.

Replace the used brush roller with a new one, or

 

 

 

 

 

 

clean and remove all debris from the present brush.

 

 

 

 

 

6.

Slide back the brush into the the fixed bearing block

 

 

 

 

 

 

in the brush house.

 

 

 

 

 

7.

Push the bearing block in its position. Lock it by

 

 

 

 

 

 

turning clockwise.

 

 

 

 

 

 

 

4

6

 

 

 

Always disconnect the power cord before performing any machine maintenance.

7

FILTERS - type of filter may vary from different models

On these machines there are two different filters; one pre-filter before the vacuum motor and one exhaust filter.

There are two different types of exhaust filters available to these machines, HEPA-filter and a standard exhaust filter. The HEPA-filter (High Efficiency Particulate Air filter) offers better filtration capacity then the standard exhaust filter. The exhaust filters catches any dirt that may escape from the dust bag, or motor pre filter. Replace the filter every fourth time that the dust bag is changed (more often in very dusty applications). The exhaust filters are located at the front side of the machine just above the brush base.

The HEPA filter can not be cleaned or washed clean. When the HEPA-filter is clogged it must be replaced.

CHANGING THE HEPA-FILTER

1. Disconnect the power cord from the electrical outlet. Push the Filter Cover Latch (19) downwards so that the cover (18) is released. Remove the filter cover from cleaner.

2. Grasp at the filter frame and remove the used and dirty HEPA-filter

3. Grasp at the filter frame and then insert the new HEPA filter to the cleaner by pushing it in place. Never touch the filter media at a HEPA-filter! Doing so may cause a loss of

12performance of the HEPA-filter).

4. Snap the Filter Cover back in place at the cleaner.

IMPORTANT!

Never operate the cleaner without the HEPA-Filter in place in the machine. Note! These machines are not designed for picking up hazardous - i.e. poisonous dust!