| Nilfisk P 130.2 / P 150.2 / P 160.2 | |||||||||||
EN | 4.8 Operation with detergents Application of detergents is | |||||||||||
|
| NOT possible if an extension | ||||||||||
|
| hose is applied. | ||||||||||
|
| 1. Fill the container with a de- | ||||||||||
|
|
| tergent. | |||||||||
|
| 2. Mount the TORNADO® PR | ||||||||||
|
|
| nozzle and adjust it to low | |||||||||
|
|
| pressure (see section 4.7). | |||||||||
|
| 3. Adjust the dosing regulator | ||||||||||
|
|
| (12) to the required volume | |||||||||
|
|
| of detergent | |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
4.Apply the detergent from below and upwards.
5.Let the detergent act for the time stated on the packing of the detergent and flush with pure water.
Separate detergent container
1.Remove the cover with suc- tion hose from the detergent container.
2.Mount the cover with suction hose on the separate deter- gent container.
The cover has a standard thread and fits common detergent con- tainers. If your container does not have a standard thread, detach the filter from the suc- tion hose and remove the cover. Remount the filter in the suction hose.
Extra detergent hose can be pulled out of the machine.
4.9 Stationary use
a
b
c
If mounting a special wall hook (not standard), the pressure washer can be used as a sta- tionary solution meaning that it can be operated while hanging on the wall.
Only mount the wall hook on a sturdy wall. Adjust the length of the screws and size of rawl- plugs to the type of wall.
On the wall hook garden/rim brush (a), brush (b) and noz- zles (c) can be stored.
Important: The bearing capacity of
the wall hook is max. 30 kg.
10