Nilfisk-Advance America P 160.2, P 130.2 Mains power connection, Safety devices, Thermal sensor

Models: P 150.2 P 160.2 P 130.2

1 20
Download 20 pages 33.31 Kb
Page 4
Image 4
Mains power connection

 

Nilfisk P 130.2 / P 150.2 / P 160.2

EN

adversely affect the safety of

 

the appliance.

Disconnect from electrical power supply before carrying out user maintenance.

To ensure the appliance safety only use original spare parts from the manufacturer or approved by the manufac- turer.

High pressure hoses, fi ttings and couplings are important for the safety of the appli- ance. Only use hoses, fi ttings and couplings recommended by the manufacturer.

Do not use the appliance if a supply cord or impor- tant parts of appliance are damaged, e.g. safety device , high pressure hose and trig- ger gun.

The appliance is intended for cleaning outdoors.

Appropriate ear protection must be used.

Never use the machine in an environment where there could be a danger of explo- sion. If any doubt arises, please contact the local authorities.

It is not allowed to clean asbestos-containing surfaces with high pressure.

This high pressure washer must not be used at tempera- tures below 0°C.

Never let any persons stay under the product when stored on the wall.

WARNING!

Inadequate extension cables can be dangerous. Cables on reels should always be com- pletely unwound to prevent the cable from overheating.

Extension cables should be of a watertight construction and comply with the below-men- tioned requirements for length and cable dimensions.

1.0 mm²

max.

12.5 m

1.5 mm²

max.

20 m

2.5 mm²

max.

30 m

If the electric cable is damaged, it must be re- placed by the manufacturer or his service agent or simi- larly qualified person in order to avoid a hazard.

Mains power connection

The following should be ob- served when connecting the high pressure washer to the electric installation:

Only connect the machine to an installation with earth con- nection.

The electric installation shall be made by a certifi ed elec- trician.

It is strongly recommended that the electric supply to this machine should include a re- sidual current device (GFCI).

Water connection Connection to the public mains according to regulations.

This high pres- sure washer is only allowed to be connected with

the drinking water

mains, when an appropriate backfl ow preventer has been installed, Type BA according

to EN 1717. The backfl ow pre- venter can be ordered under number 106411177. The length of the hose between the back-

ow preventer and the high pressure washer must be at least 10 metres to absorb pos- sible pressure peaks (min diam- eter ½ inch).

Operation by suction (for ex- ample from a rainwater vessel) is carried out without backfl ow preventer. Recommended suc- tion set: 126411387.

As soon as water has flown through the BA valve, this water is not considered to be drinking water any more.

IMPORTANT! Only use wa- ter without any impurities. If there is a risk of silt, sand or sediment in the inlet water (i.e. from your own well), an addi- tional filter should be mounted.

Repair and maintenance WARNING! Always remove the electric plug from the socket be- fore carrying out maintenance work on the machine.

Safety devices

Locking device on spray handle (7a) (see illustration at the end of this manual):

The spray handle features a locking device. When the button is activated, the spray handle cannot be operated.

Thermal sensor:

A thermal sensor protects the motor against overloading. The machine will restart after a few minutes when the thermal sen- sor has cooled.

Pressure safety device

An integrated hydraulic safety valve protects the system from excessive pressure.

4

Page 4
Image 4
Nilfisk-Advance America P 160.2, P 130.2 Mains power connection, Safety devices, Thermal sensor, Pressure safety device