ATTIX 9 H/M

8 Troubleshooting

 

Fault

 

 

Cause

 

 

Remedy

 

‡ Motor does not start

>

Fuse of the mains socket has

Connect mains fuse.

 

 

 

 

 

blown.

 

 

 

 

 

 

 

>

Overload protection switch

Switch off the vacuum cleaner

 

 

 

 

has tripped.

 

and allow it to cool for approx.

 

 

 

 

 

 

5 minutes. If the cleaner

 

 

 

 

 

 

 

cannot be started again,

 

 

 

 

 

 

 

contact the Nilfisk-Alto service

 

 

 

 

 

 

department.

 

 

 

 

>

Motor is faulty.

Have motor changed by

 

 

 

 

 

 

 

Nilfisk-Alto Service.

 

 

 

 

 

 

 

‡ Motor does not run in

>

Power tool/pneumatic tool is

Check that the power tool

 

 

automatic mode 1)

 

 

defective or not connected

 

works or that the plug is

 

 

 

 

 

properly.

 

inserted correctly.

 

 

 

 

> The power rating of the

Note that minimum power

 

 

 

 

 

electrical tool is too low.

 

rating is P>40W

 

 

 

 

 

 

 

 

 

The acoustic

warning

>

Suction power selected with

Set suction power in

 

 

sounds. (Reduced

suction

 

suction power control is too

 

accordance with section

 

 

power)

 

 

low.

 

„Setting suction power“.

 

 

 

 

>

Hose diameter does not cor-

Set correct switch position for

 

 

 

 

respond with switch position.

 

hose diameter.

 

 

 

 

>

Clogged suction hose/nozzle.

Clean suction hose/nozzle

 

 

 

 

> The safety filter bag is full.

See section „Replacing the fil-

 

 

 

 

 

 

ter bag“.

 

 

 

 

 

> Filter element is clogged.

See section „Cleaning filter

 

 

 

 

 

 

element“ and „Replacing filter

 

 

 

 

 

 

element“.

 

 

 

 

>

Cleaning mechanism is

Contact Nilfisk-Alto Service.

 

 

 

 

defective.

 

 

 

 

 

 

 

 

 

‡ No suction power during

>

Tank is full.

Switch off the cleaner. Empty

 

wet cleaning

 

 

 

 

the tank.

 

 

 

 

 

 

 

 

Voltage fluctuations

>

Impedance of power supply is

Connect the cleaner to another

 

 

 

 

too high.

 

socket closer to the fuse box.

 

 

 

 

 

 

Voltage

fluctuations

over

 

 

 

 

 

 

7% should not occur if the

 

 

 

 

 

 

impedance at the transfer point

 

 

 

 

 

 

is 0.15 Ω .

 

 

 

 

 

 

 

 

 

 

26

1) Optional accessories / Option depending on model

 

Original Instructions

Page 27
Image 27
Nilfisk-ALTO ATTIX 965-0H/M SD XC, ATTIX 965-2H/M SD XC manual Troubleshooting, Fault Cause Remedy