ATTIX 9 H/M
Electrical connection | 1. It is recommended that the vacuum cleaner should be connected | |||
| via a residual current circuit breaker. |
| ||
| 2. Arrange the electrical parts (sockets, plugs and couplings) and | |||
| lay down the extension lead so that the protection class is main- | |||
| tained. |
|
| |
| 3. Connectors and couplings of power supply cords and extension | |||
| leads must be watertight. |
|
| |
Extension lead | As an extension lead, only use the version specified by the manufac- | |||
| turer or one of a higher quality. |
| ||
| When using an extension lead, check the minimum | |||
| of the cable: |
|
| |
|
|
|
|
|
| Cable length |
| Cross section | |
|
|
| < 16 A | < 25 A |
| up to 20 m |
| 1.5 mm2 | 2.5 mm2 |
| 20 to 50 m |
| 2.5 mm2 | 4.0 mm2 |
Maintenance, cleaning and | During the following work, ensure that dust is not unnecessarily | |||
repair | spread around. Wear a P2 breathing mask. |
|
Only carry out maintenance work described in the operating instruc- tions.
Always pull out the mains plug before cleaning and maintenance of the vacuum cleaner.
During maintenance and cleaning, handle the vacuum cleaner in such a manner that there is no danger for maintenance staff or other persons.
In the maintenance area
1.Use filtered compulsory ventilation
2.Wear protective clothing
3.Clean the maintenance are so that no harmful substances get into the surroundings
Before removing the vacuum cleaner from the area contaminated with harmful substances:
1.Clean the outside of the vacuum cleaner, wipe it clean or pack the vacuum cleaner in well sealed packaging
2.and avoid spreading deposited harmful dust.
Warning: Do not reuse the essential filter element after removal out of the appliance (only for class H appliances).
4 | 1) OEL = Occupational Exposure Limit |
| Original Instructions |