ENGLISH
USER MANUAL
Electrical components | Values | ||
Electrical system voltage | 24 | V | |
|
|
| |
Vacuum system motor | 310 | W, 3,000 rpm | |
|
|
| |
Main broom motor | 500 | W, 550 rpm | |
|
|
| |
Drive system motor | 750 | W, 315 rpm | |
|
|
| |
Side broom reduction unit | 90 | W, 85 rpm | |
|
|
| |
Filter shaker motor | 90 | W, 5700 rpm | |
Closed pocket filter shaker motor (optional) | 110 W, 3,000 rpm |
Batteries | Values |
Standard WET batteries with acid electrolyte, in serial connection | Four 6 V 180 Ah batteries |
|
|
Optional WET battery with acid electrolyte | One 24 V 240 Ah battery |
|
|
Optional WET or GEL batteries available at any Nilfisk Retailer | Total voltage 24 V |
|
|
Battery maximum capacity | 330 Ah |
Battery case size (length x width x height) | 800 x 300 x 150 mm |
Battery compartment maximum size (width x length x height) | 800 x 360 x 380 mm |
Dust vacuuming and filtering |
| Values |
Paper dust filter |
| 3.6 m2 |
|
|
|
Main broom compartment vacuum |
| 10.9 mm/H2O |
Hopper hydraulic lifting system |
| Values |
| ||
|
|
|
Pump |
| Parker 108 AE S32 - 24 V |
|
|
|
Maximum pressure |
| 110 Bar |
|
|
|
Oil tank capacity |
| 0.75 litres |
|
|
|
Hydraulic circuit total capacity |
| 1.4 litres |
|
|
|
Hydraulic system oil (at ambient temperature above 10°C) |
| AGIP Arnica 46 (*) |
|
|
|
CAUTION!
If the machine is to be used at ambient temperatures below +10°C, the oil should be changed with equivalent oil having a viscosity of 32 cSt. For temperatures below 0°C, use an oil with lower viscosity.
(*)See the oil technical data and reference data tables below.
TECHNICAL DATA
AGIP ARNICA |
| 46 | 32 |
Viscosity at 40°C | mm2/s | 45 | 32 |
|
|
|
|
Viscosity at 100°C | mm2/s | 7.97 | 6.40 |
|
|
|
|
Viscosity index | / | 150 | 157 |
|
|
|
|
Flash point COC | °C | 215 | 202 |
Pour point | °C | ||
|
|
|
|
Density at 15°C | kg/l | 0.87 | 0.865 |
|
|
|
|
REFERENCE DATA
ISO 11158
AFNOR NF E 48603 HV
AISE 127
ATOS Tab. P
BS 4231 HSE
CETOP RP 91 H HV
COMMERCIAL HYDRAULICS
Danieli Standard 0.000.001 (AGIP ARNICA 22, 46, 68)
EATON VICKERS
EATON VICKERS
DIN 51524 t.3 HVLP
LAMB
LINDE
PARKER HANNIFIN (DENISON)
REXROTH RE
10