OPTIONAL BLOWER PACK ( |
| RESETABLE | |||
|
|
|
|
| |
TRANSFORMER |
|
|
|
| THERMODISC ( N.C. ) |
( IF REQUIRED ) | 3 A |
| TWO SPEED SWITCH | FAN |
|
|
| HIGH | T | ||
| FUSE |
|
|
| |
|
| LOW |
|
| |
| S |
|
|
| |
|
|
|
|
| |
| FAN | 24 V | THERMODISC ( N.O. ) | OPTIONAL BLOWER PACK | |
| RELAY | COIL | |||
|
|
| MOUNTED ON/OFF HUMIDISTAT | ||
|
|
| T | ||
INTERNAL |
|
| or JUMPER | ||
| 81 82 83 84 85 |
| |||
EXTERNAL |
|
|
| ||
|
|
|
|
BLOWER | DEDICATED |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| OPTIONAL REMOTE | ||||
PACK |
|
|
|
|
|
|
|
|
|
|
|
|
| OPTIONAL | |||||||
DISCONNECT |
|
|
|
|
|
|
|
|
|
|
|
|
| YELLOW, GREEN | |||||||
TERMINAL |
|
|
|
| JUMPER OR |
|
|
|
|
| |||||||||||
BY OTHERS |
|
|
|
|
|
|
|
|
| MODULATION | |||||||||||
|
|
|
|
|
|
|
|
|
| AND RED | |||||||||||
|
|
|
| ON/OFF |
|
|
|
|
|
|
|
|
| ||||||||
BLOCKS | S S S |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
| GROUND |
| CONTROLS |
|
|
|
|
|
| SEE EX. W.D. | INDICATORS | ||||||||||
|
|
|
|
|
|
|
|
| |||||||||||||
|
| CLAMP |
| IN SERIES |
|
|
|
|
|
|
|
|
| Y | G | R | |||||
EXTERNAL | L3 | L2 | L1 |
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
x | x | x |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
INTERNAL |
|
| G |
|
|
| 8 10 | 81 82 83 84 85 32 30 28 26 61 20 62 40 63 36 | |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| PRI. TERMINAL |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
| BLOCK OR |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
TRANSFORMER |
|
|
| OPTIONAL FUSE |
|
| MAIN SWITCH |
|
|
|
|
|
|
|
| ||||||
3 PHASE |
|
|
| BLOCK ( NHMC | 3 A | 0N |
|
|
|
|
|
|
| ||||||||
|
|
| 030 OR SMALLER) |
|
|
| 1/3 |
|
|
|
|
|
|
|
| ||||||
CONNECTION |
|
|
| FUSE |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
| OFF |
|
|
|
|
|
|
| |||
S S S |
|
|
|
|
| S |
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| 1/2 |
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
| 24 V |
|
|
|
| 1/1 |
| DRAIN |
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
| 500 OHM |
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
| STEP DOWN |
|
|
|
|
| 2/3 |
|
|
|
|
| 2 WATT |
|
|
| ||
OPTIONAL |
|
|
|
|
|
|
|
|
|
|
|
|
|
| RESISTOR |
|
|
| |||
|
|
| TRANSFORMER |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
S S S |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
INTERNAL |
|
| DOOR |
|
|
|
| 2/2 | 2/1 |
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
FUSE BLOCK |
|
|
|
|
| INTERLOCK |
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
(N HMC 050 |
|
|
|
|
| SWITCH |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
OR LARGER) |
|
|
|
| 24 V |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
| COIL |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| CONTACTOR(S) |
| FILL |
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
| 24 V |
|
|
|
|
|
|
|
|
| |
|
|
|
|
| 24 V |
|
| VALVE |
| COIL |
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
| COIL |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| DRAIN |
| 24 V |
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| VALVE |
|
| COIL |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
| 3 | 4 | HIGH |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| WATER |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
| SENSOR |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| 2 1 |
|
|
|
|
|
|
|
|
|
|
| STATUS |
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| INDICATOR |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| LED's |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| _Y _G |
|
|
|
|
|
|
|
|
|
| RED WIRE |
|
| 6 8 10 |
| 14 | 12 | 16 | 4 22 24 | 32 30 28 26 | 18 | 20 | ||||
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
| S |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 44 46 48 42 |
|
|
| S Si 1 |
|
| NHMC MAIN BOARD |
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| c/w PIGGY BACK BOARD |
| ||||||
|
|
|
|
|
|
|
|
|
|
| Si 2 |
|
|
|
|
| |||||
|
|
|
|
|
| K3 |
| K2 |
|
|
| X3 |
|
| X2 |
|
| X4 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| Si 1= 3.15A FUSE |
|
|
|
|
|
| |||||
|
|
|
|
|
| 38 34 36 40 |
| Si 2= 3.15A FUSE |
| LCD DISPLAY |
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| OPTIONAL LCD/KEYPAD DISPLAY |
|
INTERNAL
RS 232
EXTERNAL
NHMC HUMIDIFIER
w OR w/o OPTIONAL BLOWER PACK
WIRING DIAGRAM NO. 94-0-A REV. 10
- 24 -