(Life varies from 500 to 2000 operating hours, as illustrated in Figure #16.)
The RESDELUX control board constantly monitors unit performance and will shut down the humidifier and alert the customer to change the cylinder. The yellow light will flash 4 times in sequence.
Figure #16
Water Conditions vs. Cylinder Life
Capacity Adjustment Setting
|
| 100% | 50% | 25% |
|
| 30 |
|
|
| 500 |
|
|
|
|
| |
|
|
|
|
| 400 |
ofHardness | 20 |
|
|
|
|
|
|
|
| 200 mg/L(ppm) | |
Grains | 10 |
|
|
| 3 |
|
|
| CaCO | ||
|
|
|
| ||
|
|
|
|
| 100 |
| 5 |
|
|
|
|
| 500 | 1000 | 2000 | 4000 | 8000 |
|
| Cylinder Life Expectancy |
|
(average operating hours)
HOW TO REMOVE THE STEAM CYLINDER
It is advisable to keep a spare cylinder in stock throughout the humidification season. When ordering a replacement steam cylinder, always quote the three or five digit model number on the label applied to the
Figure #17
Cylinder Replacement
cylinder or quote the unit’s serial number, model and voltage located on the spec label (nameplate).
1.Turn off the water supply to the unit.
2.The used cylinder must be drained completely before removal. If the water has just been boiling, allow it to cool before draining. Push the ON/OFF/DRAIN switch to the MANUAL DRAIN position. Leave it in this position just long enough to drain the cylinder (usually not longer than 3 minutes).
3.When completely drained, push the main ON/OFF/DRAIN switch back to the OFF position.
4.Once drained, disconnect all power supplies to the unit.
5.Open the front cover door.
6.Cylinder plugs are attached to the primary voltage cylinder wires. Remove cylinder plugs from cylinder pins by pulling vertically.
7.Using a slotted screwdriver, loosen the steam hose clamp(s) and pull the steam hose off the cylinder vertically.
8.The cylinder is now ready to be lifted out of the unit. CAUTION: Cylinder and any undrained water might still be HOT.
9.Remove the used cylinder as previously described. NORTEC does not recommend the use of any acid solutions to clean the used cylinder. Always replace a used cylinder.
HOW TO INSTALL THE REPLACEMENT CYLINDER
1.Reverse procedure should be followed to install a new cylinder. Main power supply to the unit must be disconnected until the cylinder is completely installed and reconnected.
2.The cylinder plug wires are
Figure #18
Reassembly Of The Drain Valve And Fill Valve
| Actuator |
|
|
| Male |
|
| Connection Tabs |
Plunger | Spring | Sleeve |
|
| |
|
| Holding Coil |
- 9 -