Coil Descaling
In hard water areas, scale
1.Mix scale remover in a 5 gallon bucket and elevate the bucket so it is higher than the pump.
2.Attach the high pressure hose to the high pressure water outlet on the machine. Do not hook up the spray gun.
3.Place the other end of the high pressure hose in the 5 gallon bucket.
4.Attach a short length of hose to the garden hose inlet on the pump.
5.Prime the pump by filling the hose with water, then place the end of the hose in the bucket.
00791
Clean Inlet Strainer
When Finished
6.Run the pressure washer in cold mode for 1 to 3 hours recirculating the cleaning solution.
Warning: Do not run the burner.
7.Dispose of the cleaning solution where it is not harmful to animals or the environment.
8.Flush with fresh water and clean the inlet strainer when finished.
Coil Desooting
Poor grades of fuel oil or inadequate combustion air will cause heavy soot
Most coils will never require desooting. However, to desoot a coil...
1.Wear protective clothing, goggles, and gloves.
2.Remove the fittings from the inlet and outlet of the coil.
3.Remove the lid from the heating chamber and hoist the coil out. Be careful, the coil is very heavy.
Important: Be careful not to damage the threads on the coil inlet and outlet. If the threads get damaged, it will be hard to reconnect and seal the fittings on the coil inlet and outlet.
Lid
Insulation Cap
Heating Coil
Heating Chamber
00792 | Short High |
| Pressure Hose |
4.Clean the coil.
5.Reassemble the coil to the machine. Make sure the white insulation remains in place.
6.Make sure all fittings are tight before using the machine. Use thread sealant on all threads.
15