V.) Getting Started
IMPORTANT: Proper initial installation of equipment will assure more satisfactory performance, longer service life, and lower maintenance cost.
Make sure the pressure washer is on a level surface and in a protected area where it is not readily influenced by outside forces such as strong winds, freezing temperatures, rain, etc. Locate the pressure washer for easy access for filling fluids, adjustments, and maintenance.
It is recommended that a partition be made between the wash area and the pressure washer to prevent direct nozzle spray from coming in contact with the pressure washer. Moisture reaching the equipment will reduce the pressure washer’s service life.
Partition
V.) Venting
DANGER: Do not run machine indoors or in an enclosed area without adequate ventilation, or in areas where flammable vapors, (gasoline, solvents, etc.) may be present. Do not vent exhaust gases into a wall, a ceiling, or a concealed space.
CAUTION: All venting must be in accordance with applicable federal and state laws, and local ordinances. Consult local heating contractors.
Poor draft will cause the pressure washer to soot and not operate properly. When selecting the location for installation, beware of poorly ventilated locations or areas where exhaust fans may cause an insufficient supply of oxygen. Proper combustion can only be obtained when there is a sufficient supply of oxygen available for the amount of fuel being burned. If it is necessary to install a unit in a poorly ventilated area, outside fresh air may have to be piped to the burner and a fan installed to bring sufficient air into the unit
VI.) Oil Burner
Burner Air Adjustment: The oil burner is preset and performance tested at the factory (elevation 1100 feet). A
Air Band
White
Arrow
Locking | Burner | |
Screw | ||
|
1.) Turn the pump and heat switches on (Refer to “Operation” for details). Have someone operate the spray gun so the burner fires.
2.) Loosen the locking screw and close the air band until black smoke appears from the burner exhaust vent. Note the position of the white arrow on the air band.
3.) Slowly open the air band until white smoke just starts to appear.
4.) Turn the air band half way back to the black smoke position previously noted. Tighten the locking screw.
5.) Fine tune the burner air by loosening the shutter lock screw and turning the shutter until the exhaust is
Shutter
Shutter Lock
Screw
cleanest. Tighten the shutter lock screw.
CAUTION: If white smoke appears from the burner exhaust vent during
9