Nova LM-700 manual User Mode Operation

Models: LM-700

1 13
Download 13 pages 22.97 Kb
Page 5
Image 5

4.0 USER MODE OPERATION

The Mercury dispensers four modes of operation are described in this section.

Automatic Mode runs each pump program (program

=delay time + run time) upon qualified input to the respective signal input. When on (not set to 000), the Lockout Timer begins at start of first pump program (beginning of delay time). During this lockout period, no pump amount may run more than once regardless of the number of times the signal input occurs. Display indicates signal status, pumps running, and lockout status. Machine operator selects desired formula number with the Scroll key. Auto Formula Select is always active, but may be overrid- den by machine operator input.

Push Button Mode relies on a user push button press to start the wash formula program. Auto Formula Select is always active, but may be overrid- den by machine operator input. The machine operator selects the formula number with the Scroll key, and then starts the wash formula program by pressing and releasing the Enter key for less than 2 seconds. Pumps run as programmed via programmed delay and run times. During the lockout time, all button presses to start the formula program are ignored except, Password input. The display indi- cates pumps running and lockout status.

Occurrence Mode is an alternate automatic logic where signals from input numbers 1, 2 and 3 act as a single logic input signal. Signal occurrences are counted (simultaneous input signals count as one signal occurrence) to determine when each pump runs, based on pump-assignments in the Assign Pump “A1A” screen in the programming menu. Pumps 1 and 2 have two programmable amounts, A and B, which are treated in Occurrence Mode as separate pump programs. Display indicates signal status, pumps running, and lockout status. Auto Formula Select is always active, but may be overrid- den by machine operator input.

Relay Mode requires no machine operator interac- tion since all dispensing system control is turned over to the washing machine control system.

NOTE:

Password input and/or power failure

 

resets the lockout timer and ends the

 

wash load in all modes.

4.1User Mode Menu Screens

Use the Next key to step through all available User Mode menu screens. The display will revert to the User Mode Home Screen after 30 seconds of inactivity.

4.1.1 Formula Selection

From the Home Screen, press the Scroll key to select programmed formulas (1-4).

NOTE:

Formulas with no amounts pro-

 

grammed may not be selected.

4.1.2 Start Formula (Push Button Mode Only)

From the Home Screen press and release the Enter key for less than 2 seconds to trigger manual dispensing.

NOTE:

To terminate wash formula before

 

end of lockout period press and hold

 

the Enter key longer than 2 seconds,

 

release, and wait 30 seconds for

 

screen to revert to idle screen.

4.1.3 View Load Counter

From the Home Screen press the Next key once to display “L”. Load counter (all formulas) will toggle between “L” and load count since last clear.

4.1.4 ID/Mode

From the Home Screen press the Next key twice to display the operating firmware ID number and currently selected operating mode. The first two digits indicate a firmware ID number we may ask you when troubleshooting. The right digit indicates the current Operating Parameter (oP) selection (1= Automatic, 2 = Push Button, 3 = Occurrence, and 4 = Relay).

4.1.5 Prime Pumps (when enabled)

From the Home Screen press the Next key three times to display “P 1”. Press the Scroll key to select pump number to prime. Press the Enter key to turn selected pump on or off.

NOTE:

Prime Pumps is only available when

 

unit is not in a lockout timer period.

 

If the dispenser is in a lockout timer

 

period the display will indicate P-0

 

and the Scroll key will not select a

 

pump number.

4.1.6 Password Access to Program Mode

From the Formula Selection screen only, press and hold the Enter Key for 2 seconds to access the Password input screen. Press the Scroll Key to change the blinking digit to the desired value. Press the Next Key to move the blinking digit. Press the Enter Key when the desired number is present in all digits to enter Program Mode. The password factory setting is 123.

THEORY OF

OPERATION

MECHANICAL

INSTALLATION

ELECTRICAL

INSTALLATION

PROGRAMMING

USER MODE

OPERATION

TROUBLESHOOTING

SPARE PARTS

LISTING

MAINTENANCE & SPECIFICATIONS

INDEX

P/N 20-07121-00 Rev. C

Page 5

Page 5
Image 5
Nova LM-700 manual User Mode Operation