2.0 MECHANICAL INSTALLATION
CAUTION: The Mercury dispensing system is intended to be installed by experi- enced installers in accordance with all applicable electrical and plumbing codes.
Disconnect power to all laundry machine and dispensers during installation and/or any time the dispenser cabinet is opened.
2.1Wall Mounting Unit
To determine a suitable location to install the dispenser, keep the following in mind:
Install close to product containers at a reasonable height for easy service access.
When intended for Push Button Mode operation, be sure to allow easy front panel access for the machine operator.
2.1.1Drill one hole in wall for upper mounting bracket screw wall anchor.
2.1.2Install wall anchor and temporarily attach bracket to the wall (do not tighten screw all the way).
2.1.3Level bracket using
2.1.4Swing bracket out of the way, drill lower holes, and install lower wall anchors.
2.1.5Screw bracket into place.
2.1.6Lower unit onto wall mount bracket and press down until unit locks into place. To remove unit from bracket, depress lock button on the top of the bracket as you lift the unit from the mounting bracket.
2.2Supply and Discharge Hoses
We recommend use of 3/8" ID hose for supply and discharge hoses. Use of smaller size ID hose/tube may results in reduced flow rates, premature pump tube failure, or both.
The maximum combined distance for supply and discharge hoses must not exceed 50 feet. The maximum supply side hose distance must not exceed 15 feet. The maximum vertical height from product container to pump must not exceed 10 feet.
Use hose clamps to secure supply and discharge hoses to pump tube hose barbs. Route supply hose to product pails and discharge hose to washer per industry standard practices.
Figure 2.0 | Lock Button |
Mounting Bracket
Level
Figure 2.1
Unit Rear Bracket Slot