![MODEL 330N WALL INLET INSTALLATION](/images/new-backgrounds/35496/3549619x1.webp)
MODEL 330N WALL INLET INSTALLATION
1.Make cutout according to dimensions in Figure 30.
2.Refer to Figure 31. Break off nail plate at scored line.
3.Refer to Figure 32. Glue elbow to mounting plate, place assembly into cutout, and attach elbow to tubing inside the wall.
4.Make sure mounting holes are exactly at top and bottom.
5.Connect
6.Refer to Figure 33. Align inlet mounting holes with mounting plate holes, place inlet into mounting plate, and secure with provided screws. NOTE: If
1/4"
23/4"
3/8" DIA.
37/8"
| 3/8" DIA. |
1/4" | 13/8" |
FIGURE 30 |
FIGURE 31
MOUNTING
PLATE
ELBOW
MOUNTING
HOLE (2)
FIGURE 32
INLET |
MOUNTING |
PLATE |
FIGURE 33 |
FLOOR INLET INSTALLATION
INSTALLATION IN NEW AND EXISTING CONSTRUCTION
1.Refer to Figures 34 and 35. After floor inlet location has been selected, cut a 31⁄16" x 29⁄16" square hole in floor. Center line of inlet must be located at least 21⁄2" from wall to allow cover to be opened when hose is inserted.
2.Determine direction of tubing and attach appropriate flanged fitting to mounting bracket with four (4) screws supplied. Be sure mounting bracket flange does not interfere with tubing and seal is securely in place.
3.Refer to Figure 36. Position bracket with frame and flanged fitting assembly into cutout from below and secure to sub floor.
4.Refer to Figure 37. Large end of Model 399 extension sleeve should be cut to length to allow proper seating of inlet against floor or carpet.
5.Refer to Figure 38. Pull Low Voltage
6.For convenience of operation, floor inlet should be installed to open back toward wall.
7.Refer to Figure 36. Secure floor inlet in place with two screws.
TOP VIEW
29/16"
31/16"
| MOLDING |
|
|
| WALL |
FIGURE 34 |
|
|
| ||
|
|
|
| ||
|
|
|
|
|
10
SIDE VIEW | 21/2" MIN. |
| APPROX. |
| MOUNTING BRACKET |
| FLANGE |
FIGURE 35 |
|