MINIMUM WALL CLEARANCE DIMENSIONS | |
12" | 18" |
| EXHAUST |
“D” |
|
| INTAKE |
TOP VIEW |
|
12" MINIMUM TO CEILING |
|
FRONT VIEW |
|
| INTAKE |
“B” TOP |
|
MOUNT |
|
BOLT |
|
| EXHAUST |
| “C” |
“A” |
|
OVERALL |
|
HEIGHT |
|
18" MINIMUM |
|
ABOVE FLOOR |
|
| FIGURE 18 |
DIMENSIONAL CHART
| MODEL |
| |||
| DIMENSION |
|
| ||
| A | 27" |
| ||
| B |
|
| 73⁄4" |
|
| C |
|
| 61⁄2" |
|
| D |
|
| 135⁄8" |
|
|
|
|
|
| |
TOP OF POWER UNIT |
|
| TOP |
| |
|
|
|
|
| |
|
| KEYHOLE SLOT |
| ||
|
|
|
|
| |
|
|
|
|
|
|
|
| 111/2" |
|
LOWER | MOUNTING | FIGURE 19 |
SLOT | BRACKET |
POWER UNIT INSTALLATION
MOUNTING See Figure 18.
1.Locate the power unit within six feet of a grounded electrical outlet.
2.Drill 3⁄16" diameter pilot holes for the two (2) mounting screws in a wall stud or strong support. See Figure 19.
3.Tighten mounting screws. Leave approximately 1⁄8" to 3⁄16" clearance between head of screw and wall.
4.Hang power unit onto mounting bolts. Make sure top keyhole slot and lower slot in mounting bracket are engaged behind mounting screws. Pull down to secure.
5.Remove dirt canister from power unit.
6.Install soil bag and securely replace dirt canister.
NOTE: Cyclonic model does not use a soil bag.
TUBING CONNECTIONS
1.Using rubber couplings and hose clamps, connect intake and exhaust tubing to the power unit.
2.Connect intake tubing to lower intake tube on power unit.
3.Connect exhaust tubing to upper exhaust tube on the power unit.
4.Make sure all tubing connections are air tight.
5.The exhaust should not be vented into a wall, a ceiling or a concealed space in the house. The exhaust line should be terminated outside the home, using Model 393 Wall Cap or a roof vent.
WIRING See Figure 20.
Grounding Instructions – This appliance must be grounded. If it should malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This appliance is equipped with a cord having an
Danger – Improper connection of the
This appliance is for use on a nominal
1.Connect low voltage wire (18 gauge,
2.The power unit is equipped with a six foot grounded cord. Plug cord into 120 volt grounded receptacle.
NOTE: POWER UNIT | WIRING |
|
|
CONTROL LEADS ARE |
| POWER UNIT | |
|
| ||
TO BE CONNECTED TO |
|
| CONTROL LEADS |
INLET LEADS WITH |
|
|
|
SUITABLE WIRE |
|
|
|
CONNECTORS. | POWER CORD | POWER |
|
|
| ||
120vAC ELECTRICAL | UNIT |
| |
|
| ||
OUTLET |
|
|
|
MODEL 376 (18/2) WIRE |
| INLET | |
| LEADS | ||
TO |
|
| |
|
|
| |
OTHER |
|
|
|
INLETS |
|
|
|
INLET | INLET | INLET | FIGURE 20 |
|
|
| 7 |