NuTone CV352 manual Power Unit Installation, Dimensional Chart, Tubing Connections

Models: CV352

1 12
Download 12 pages 27.7 Kb
Page 7
Image 7
DIMENSIONAL CHART

MINIMUM WALL CLEARANCE DIMENSIONS

12"

18"

 

EXHAUST

“D”

 

 

INTAKE

TOP VIEW

 

12" MINIMUM TO CEILING

 

FRONT VIEW

 

 

INTAKE

“B” TOP

 

MOUNT

 

BOLT

 

 

EXHAUST

 

“C”

“A”

 

OVERALL

 

HEIGHT

 

18" MINIMUM

 

ABOVE FLOOR

 

 

FIGURE 18

DIMENSIONAL CHART

 

MODEL

 

 

DIMENSION

 

CV-352

 

 

A

27"

 

 

B

 

 

734"

 

 

C

 

 

612"

 

 

D

 

 

1358"

 

 

 

 

 

 

TOP OF POWER UNIT

 

 

TOP

 

 

 

 

 

 

 

 

KEYHOLE SLOT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

111/2"

 

LOWER

MOUNTING

FIGURE 19

SLOT

BRACKET

POWER UNIT INSTALLATION

MOUNTING See Figure 18.

1.Locate the power unit within six feet of a grounded electrical outlet.

2.Drill 316" diameter pilot holes for the two (2) mounting screws in a wall stud or strong support. See Figure 19.

3.Tighten mounting screws. Leave approximately 18" to 316" clearance between head of screw and wall.

4.Hang power unit onto mounting bolts. Make sure top keyhole slot and lower slot in mounting bracket are engaged behind mounting screws. Pull down to secure.

5.Remove dirt canister from power unit.

6.Install soil bag and securely replace dirt canister.

NOTE: Cyclonic model does not use a soil bag.

TUBING CONNECTIONS

1.Using rubber couplings and hose clamps, connect intake and exhaust tubing to the power unit.

2.Connect intake tubing to lower intake tube on power unit.

3.Connect exhaust tubing to upper exhaust tube on the power unit.

4.Make sure all tubing connections are air tight.

5.The exhaust should not be vented into a wall, a ceiling or a concealed space in the house. The exhaust line should be terminated outside the home, using Model 393 Wall Cap or a roof vent.

WIRING See Figure 20.

Grounding Instructions – This appliance must be grounded. If it should malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This appliance is equipped with a cord having an equipment-grounding conductor and grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

Danger – Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt as whether the outlet is properly grounded. Do not modify the plug provided with the appliance – if it will not fit the outlet, have a proper outlet installed by a qualified electrician.

This appliance is for use on a nominal 120-volt circuit and has a grounding plug. Make sure that the appliance is connected to an outlet having the same configuration as the plug. No adapter should be used with this appliance.

1.Connect low voltage wire (18 gauge, 2-conductor, Model 376) to two low voltage wires located on outside of the power unit.

2.The power unit is equipped with a six foot grounded cord. Plug cord into 120 volt grounded receptacle.

NOTE: POWER UNIT

WIRING

 

 

CONTROL LEADS ARE

 

POWER UNIT

 

 

TO BE CONNECTED TO

 

 

CONTROL LEADS

INLET LEADS WITH

 

 

 

SUITABLE WIRE

 

 

 

CONNECTORS.

POWER CORD

POWER

 

 

 

120vAC ELECTRICAL

UNIT

 

 

 

OUTLET

 

 

 

MODEL 376 (18/2) WIRE

 

INLET

 

LEADS

TO

 

 

 

 

 

OTHER

 

 

 

INLETS

 

 

 

INLET

INLET

INLET

FIGURE 20

 

 

 

7

Page 7
Image 7
NuTone CV352 Power Unit Installation, Dimensional Chart, Tubing Connections, NOTE Cyclonic model does not use a soil bag