OPERATIONAL CHECKOUT

Diagnostic Tests

The following diagnostic test have been incorporated into the NuTone IMA-3303 Radio Intercom to assist in system troubleshooting.

1.Master station keyboard test

2.Control line voltage test

3.Display test

The following applies to all three diagnostic tests:

1.To access any of the diagnostic tests, the system must be in the quiescent state (radio off and intercom in the standby mode).

2.Pressing the MEMORY SET key will end the current diagnostic test.

3.The current diagnostic test will end after one minute of inactivity.

NOTE: An incorrect control line voltage caused by miswiring

or a defective remote station may prevent the unit from entering the diagnostic mode. This condition, however, can

be circumvented by first placing all station selector switches into the OFF mode and then disconnecting CN701 from the terminal board. The voltage on the control line can then be measured by activating the control line voltage test mode and then reconnecting CN701.

1.MASTER STATION’S KEYBOARD TEST – Verifies that all keys on the master station are functioning properly. To Activate: Press and HOLD

1.key

2.key

3.MEMORY 1 key.

In this mode the hours in the display represent the current diagnostic test and the minutes indicate the current key being pressed. The following will be displayed as each key is pressed.

KEY

DISPLAY

No key pressed

1:00

SCAN

1:01

1:02

1:03

PROGRAM OFF

1:04

AM

1:05

FM

1:06

CD/TAPE

1:07

AUX

1:08

TIMER

1:09

INSIDE/PATIO

1:10

DOOR TALK

1:11

END CALL

1:12

MEMORY 1

1:13

MEMORY 2

1:14

MEMORY3

1:15

MEMORY 4

1:16

MEMORY 5

1:17

MEMORY 6

1:18

TIME SET

1:19

HOUR

1:20

MIN

1:21

MEMORY SET

1:22

 

 

2.CONTROL LINE VOLTAGE TEST – Displays the voltage on the control line.

To activate: Press and HOLD

1.key

2.key

3.MEMORY 2 key.

Example:

 

VOLTAGE ON

DISPLAY

CONTROL LINE

2:34

3.4 volts

2:17

1.7 volts

2:06

.6 volts

 

 

In this mode, the hours represent the diagnostic test, and the minutes indicate the voltage on the control line.

 

VOLTAGE WINDOW

MODE

MAX

 

MIN

End Call

4.5V

-

2.4V

Door Talk

2.4V

- 1V

Inside/Patio

1.0V

-

0

 

 

 

 

The control line voltage windows for the three intercom modes are listed above. For proper intercom operation, the control voltage produced when an intercom key is pressed at a remote station should fall between the voltages indicated.

NOTE: Pressing END CALL, DOOR TALK or INSIDE/PATIO keys at the master station will not change the voltage on the control line.

If a remote station does not produce a voltage within the above windows for a specific intercom function, check the following:

Make sure all connectors from the master station are properly installed into the terminal PC board.

Check IWA-3 connections at the terminal PC board and at each remote station.

Confirm that the suspect remote speaker station functions properly by replacing it with a known good Remote Station.

3.DISPLAY TEST – Displays all of the segments in the display. To Activate: Press and HOLD

1.key

2.key

3.MEMORY 3 key

Pressing the key toggles the display on and off.

1111

Page 11
Image 11
NuTone IMA-3033 Series Master Station installation instructions Operational Checkout, Diagnostic Tests