TROUBLESHOOTING
PROBLEM | PROBABLE CAUSE | SOLUTION |
Pilot will not light | Tank fuel empty | Replace LPG tank |
| Opening blocked | Clean or replace opening |
| Air in supply system | Purge air from lines |
| Loose connections | Check all fittings |
Pilot will not stay on | Debris around pilot | Clean dirty area |
| Loose connections | Tighten connections |
| Thermocouple bad | Replace thermocouple |
| Gas leak in line | Check connections |
| Lack of fuel pressure | Tank near empty. Replace LPG |
|
| tank. |
Burner will not light | Pressure is low |
| Opening blocked |
| Control not ON |
| Thermocouple bad |
| Pilot light assembly bent |
| Not in correct location |
Tank near empty. Replace LPG tank.
Remove and clean Turn valve to ON Replace thermocouple Place pilot properly Position properly and retry
12