Oki C5510 instruction manual To Replace Regulator

Models: C5510

1 28
Download 28 pages 63.46 Kb
Page 22
Image 22

To Replace Regulator

1.Release all air pressure from air tank. See "To Drain Tank" in the "Maintenance" section.

2.Set the On/Auto/Off lever to "Off" and unplug unit.

3.Using an adjustable wrench remove the outlet pressure gauge and quick connect from the regulator.

4.Remove the regulator.

Quick

Outlet Pressure Gauge

Connect

 

Regulator

5.Apply pipe sealant tape to the nipple on the standpipe.

Regulator

Regulator

Nipple

Arrow

6.Assemble the regulator and orient as shown.

NOTE: Arrow indicates flow of air. Make sure it is pointing in the direction of air flow.

7.Reapply pipe sealant to outlet pressure gauge and quick connect.

8.Reassemble outlet pressure gauge and quick connect. Orient outlet

pressure gauge to read correctly. Tighten connect with wrench.

A10260