Chapter 3 20 Point Linearization (-LIN option)

3.1 20 Point Linearization Operation (-LIN option)

A 20 point linearization table is used to construct a curve describing the relationship of K-Factor and input frequency. The measured input frequency is used to access the table. A linear interpolation of adjacent point pairs is used to arrive at the K-Factor at that input frequency. The fl ow rate and total are then com- puted based upon the K-Factor for that measurement sample.

NOTE: For best performance and resolution choose as many decimal places as possible in the K- Factor.

Example: Enter a K-Factor of 1 as 1.000.

Chapter 4 Programming

4.1 Explanation of Display Prompts

Save Total : (Save Total) Press the E key while the unit is running to save the total value. The display will show

"save total " for a few seconds. This is a very useful "scratch pad" to save and restore total when replacing the battery(ies)

ent Code : (enter code) This prompt will only appear if the panel lock is ON. Press the key to increment each digit. Press the key to step to the next digit to the left. Press the E key to enter the 5 digit code. If the entered code is correct, the display will advance to the next menu prompt (CLr tot). If incorrect, the display will return to the run mode.

Clr tot : (clear total) Clears (resets) the totalizer. Press the E key to clear the total and return to the run mode. Press the M key to skip and advance to the next menu selection.

fdeC : (factor decimal) Sets the decimal location for the factor. This location is restricted to 3 places (99.999). The use of this decimal automatically limits the number of decimal locations allowable in the rate and total to acceptable ranges. Press the key to move the decimal. Press the E key to select the displayed decimal location.

NOTE: For best performance and resolution choose as many decimal places as possible in the K-Factor. Example: Enter a K-Factor of 1 as 1.000.

faC lInear/20poInt : (factor type) This prompt will only appear if the unit is ordered with the 20 point linearization op- tion. The 20 poInt linearization selection is recommended for fl ow meters whose K-factors change with different

ow rates. This selection allows users to enter up to 20 different frequencies with 20 corresponding K-factors for different fl ow rates. The lInear setting is used for fl ow meters whose output is linear over its' entire operating

ow range. Press the key to step to the desired choice. Press the E key to enter the displayed factor type.

No / yes set Pnts : (set 20 point?) This prompt allows the user to skip the 20 point setup routine. Select yes for initial setup or to change the present 20 point values. Select No to skip and keep the existing values.

faC : (factor) This prompt appears on all units with linear inputs. The Factor is the number of pulses per unit volume for the fl ow sensor. The pulses/unit volume is implied by the totalizer descriptor when a descriptor is used. The implied units for the Factor are then as follows:

GAL

pulses/gallon

LIT

pulses/liter

FT3

pulses/ft3

M3

pulses/M3

Factors from 0.0001 to 99999999 may be used. A "0" value for the factor is not allowed and the unit will default to "1" in LSD if a "0" entry is attempted . The factor is displayed on the subsidiary (lower) display. Press the key to increment each digit. Press the key to step to the next digit to the left. Press the E key to enter the displayed factor.

5

Page 9
Image 9
Omega DPF500 Series manual Programming Explanation of Display Prompts, FT3