Error Code Message Information

MEM0009

Message

 

Memory device at location <location> is throttled.

 

 

 

Details

 

System performance is degraded.

 

Action

 

If unexpected, review system logs for power or thermal exceptions.

MEM0010

Message

 

Memory device at location <location> is over heating.

 

 

 

LCD Message

Memory device <location> is over heating. Check fans.

 

Details

 

System performance is degraded.

 

Action

 

If unexpected, review system logs for power or thermal exceptions.

MEM0022

Message

Memory device at location <location> is absent.

 

 

Details

The memory may not be seated correctly, misconfigured, or has failed. Memory size is

 

 

reduced.

 

Action

Re-seat the memory modules. If the issue persists, see Getting Help.

MEM0701

Message

Correctable memory error rate exceeded for <location>.

 

 

Details

The memory may not be operational. This an early indicator of a possible future

 

 

uncorrectable error.

 

Action

Re-seat the memory modules. If the issue persists, see Getting Help.

MEM0702

Message

 

Correctable memory error rate exceeded for <location>.

 

 

 

LCD Message Correctable memory error rate exceeded for <location>. Re-seat memory.

 

Details

 

The memory may not be operational. This an early indicator of a possible future

 

 

 

uncorrectable error.

 

Action

 

Re-seat the memory modules. If the issue persists, see Getting Help.

MEM1001

Message

 

Memory device at location <location> failed to transition to a running state.

 

 

 

LCD Message Memory device <location> failed to transition to a running state. Re-seat memory

 

Details

 

The memory may not be operational. This an early indicator of a possible future

 

 

 

uncorrectable error.

 

Action

 

Re-seat the memory modules. If the issue persists, see Getting Help.

MEM1003

Message

Memory device at location <location> failed to transition to in test.

 

 

Details

The memory may not be operational. This an early indicator of a possible future

 

 

uncorrectable error.

 

Action

Re-seat the memory modules. If the issue persists, see Getting Help.

MEM1012

Message Memory device at location <location> is in a degraded state.

 

83

Page 83
Image 83
Dell QHB Error Code Message Information MEM0009, MEM0010 Message, MEM0022 Message, MEM0701 Message, MEM0702 Message