Error Code Message Information
SEL1302
SEL1304
SEL1306
SEL1308
SEL1501
SEL1502
SEL1504
Details | System setup displays the system boot order. The local video screen may also show |
| additional information. (IPMI sensor type code 1eh - offset 00h). |
Action | Check system boot settings. Check if mass storage controller configuration settings are |
| applicable. |
Message | |
Details | The disk in the drive is not formatted correctly or does not contain the necessary operating |
| system files. |
Action | Replace diskette with a bootable disk. |
Message | The PXE server not found. |
Details | PXE is one way to boot a system from the network. |
Action | Check the network and PXE server configuration. |
Message | Invalid boot sector found. |
Details | The disk in the drive is not formatted correctly or does not contain the necessary operating |
| system files. |
Action | Replace diskette with a bootable disk. |
Message | A |
Details | The system has failed to boot to an operating system and needs the user to select a boot |
| source. |
Action | Select boot source within the time allowed. |
Message | Chassis management controller (CMC) redundancy is lost. |
Details | An action or failure has taken place that breaks CMC redundancy. |
Action | Check the CMC network cables and network connections. Check that CMC firmware |
| versions match. |
Message | Chassis management controller (CMC) redundancy is degraded. |
Details | An action or failure has taken place that breaks CMC redundancy. |
Action | Check the CMC network cables and network connections. Check that CMC firmware |
| versions match. |
Message | The chassis management controller (CMC) is not redundant. Insufficient resources to |
| maintain normal operations. |
Details | There is not enough available power for two CMC's to operate. |
Action | Check the overall power consumption and power status. |
104