Dell QHB owner manual Additional information. Ipmi sensor type code 1eh offset 00h

Models: QHB

1 121
Download 121 pages 28.19 Kb
Page 104
Image 104

Error Code Message Information

SEL1302

SEL1304

SEL1306

SEL1308

SEL1501

SEL1502

SEL1504

Details

System setup displays the system boot order. The local video screen may also show

 

additional information. (IPMI sensor type code 1eh - offset 00h).

Action

Check system boot settings. Check if mass storage controller configuration settings are

 

applicable.

Message

Non-bootable diskette detected.

Details

The disk in the drive is not formatted correctly or does not contain the necessary operating

 

system files.

Action

Replace diskette with a bootable disk.

Message

The PXE server not found.

Details

PXE is one way to boot a system from the network.

Action

Check the network and PXE server configuration.

Message

Invalid boot sector found.

Details

The disk in the drive is not formatted correctly or does not contain the necessary operating

 

system files.

Action

Replace diskette with a bootable disk.

Message

A time-out occurred while waiting for user to select a boot source.

Details

The system has failed to boot to an operating system and needs the user to select a boot

 

source.

Action

Select boot source within the time allowed.

Message

Chassis management controller (CMC) redundancy is lost.

Details

An action or failure has taken place that breaks CMC redundancy.

Action

Check the CMC network cables and network connections. Check that CMC firmware

 

versions match.

Message

Chassis management controller (CMC) redundancy is degraded.

Details

An action or failure has taken place that breaks CMC redundancy.

Action

Check the CMC network cables and network connections. Check that CMC firmware

 

versions match.

Message

The chassis management controller (CMC) is not redundant. Insufficient resources to

 

maintain normal operations.

Details

There is not enough available power for two CMC's to operate.

Action

Check the overall power consumption and power status.