Error Code Message Information
LCD Message | SBE log disabled on <location>. |
Details | Errors are being corrected but no longer logged. |
Action | Review system logs for memory exceptions. reinstall memory at location <location>. |
OSE0000
OSE0001
OSE0004
OSE0005
OSE1001
OSE1003
OSE1005
OSE1007
Message A critical stop occurred during OS load.
Details The system halted due to an exception during operating system load or operating system initialization.
Action Review operating system logs and system video for additional information.
Message A runtime critical stop occurred.
Details The system halted due to an exception while the operating system was running. This is a kernel panic or bug check event.
Action Review operating system logs and system video for additional information.
Message A soft
Details A separate exception or status condition shutdown the operating system. (IPMI sensor type 20h - offset 04h).
Action Review system event log for platform events capable of shutting the system down.
Message Agent is not responding.
Details Graceful shutdown request to an agent via the BMC did not occur due to a system hardware or software exception.
Action Review operating system logs and system video for additional information.
Message Failed to boot from A.
Action Review system boot configuration and boot media. Verify the media in a: is bootable. See system video for additional information.
Message Failed to boot from C.
Action Review system boot configuration and boot media. Verify the media in C: is bootable. See system video for additional information.
Message PXE boot failed.
Action Review system boot configuration, local PXE configuration, and PXE server configuration.
Message Diagnostic boot failed.
Action Review system boot configuration and boot media. See system video for additional information.