Error Code Message Information
PSU0006 | Message | Power supply <number> type mismatch. |
| ||
| LCD Message | Power supply <number> is incorrectly configured. Check PSU. |
| Details | Power supplies should be of the same input type and power rating. |
| Action | Install matched power supplies and review proper configuration in this manual. |
PSU0007
PSU0008
PSU0016
PSU0031
PSU1201
PSU1202
Message Power supply <number> is operating at 110 volts, and could cause a circuit breaker fault.
Details A power supply that is designed to operate at 220V, but is connected to a 110V power source requires additional current for operation. The additional current may trip circuit- breakers or cause other electrical issues with the input source.
Action Check input power source and cabling. Use recommended input power. Review this Manual. If the issue persists, see Getting Help.
Message Power supply <number> voltage rating does not match the system's requirements.
Details The system does not support mixed voltage power supplies.
Action Install a power supply with the correct voltage rating.
Message | Power supply <number> is absent. |
LCD Message | PSU <number> is absent. Check PSU. |
Details | The supply has been removed or has failed. |
Action | 1. | Remove and reinstall the power supply. |
| ||
| 2. | Check cables and subsystem components in the system for damage. |
| 3. | If the issue persists, see Getting Help. |
Message Cannot communicate with power supply <number>.
LCD Message Cannot communicate with PSU <number>.
Details The power supply may operate, however power supply monitoring will be degraded. System performance may be degraded.
Action | Remove and reinstall the power supply. If the issue persists, see Getting Help. |
Message Power supply redundancy is lost.
Details The power supply will try to operate in a degraded state. System Performance and power redundancy may be degraded or lost.
Action Check input power. Reinstall the power supply. If the issue persists, see Getting Help.
Message Power supply redundancy is degraded.
Details The power supply will try to operate in a degraded state. System Performance and power redundancy may be degraded or lost.
96