Error Code Message Information
CPU0805 Message The power input for CPU <
number
> voltage regulator module is outside of range, but it is
attached to the system.
Details System performance may be degraded or the system may fail to operate.
Action 1. Turn system off and remove input power for one minute.
2. Reapply input power and turn system on.
3. Ensure the processor is seated correctly.
4. If the issue persists, see Getting Help.
CPU0806 Message CPU <
number
> voltage regulator module is incorrectly configured.
LCD Message CPU <
number
> voltage regulator module incorrectly configured. Check configuration.
Details System performance may be degraded or the system may fail to operate.
Action Review this manual for proper configuration and installation procedures.
CPU0816 Message CPU <
number
> voltage regulator module is absent.
LCD Message CPU <
number
> voltage regulator module absent. Check module.
Details System performance may be degraded or the system may fail to operate.
Action If removal was unintended, check presence and reinstall.
HWC1001 Message The <
name
> is absent.
LCD Message The <
name
> is absent. Check hardware.
Details The absent device may be necessary for proper operation. System functionality may be
degraded.
Action Reinstall or reconnect the hardware.
HWC1002 Message The <
name
> is disabled.
Action If device disabled unexpectedly, re-enable device.
HWC1005 Message The storage adapter is absent.
LCD Message The storage adapter is absent. Check hardware.
Details The storage adapter may be necessary for proper operation. System functionality may
be degraded.
Action Install storage adapter.
HWC1006 Message The storage adapter is disabled.
Action If adapter disabled unexpectedly, re-enable the storage adapter.
77