Dell QHB owner manual Cmc

Models: QHB

1 121
Download 121 pages 28.19 Kb
Page 105
Image 105

Error Code Message Information

SEL1506

Message

Lost communications with Chassis Group Member <number>.

 

 

Details

The primary CMC has lost communication with the indicated member CMC.

 

Action

Check the network cable and network connections.

SEL1508

SEL1510

SEL9900

SWC4004

SWC4006

SWC4008

Message

Member <number> could not join the Chassis Group.

Details

The indicated member CMC is a leader of a different CMC stacking group.

Action

Check if member CMC is a leader of a different chassis group.

Message

An authentication error detected for Chassis Group Member <number>.

Details

Group master CMC could not log into the group member CMC.

Action

Check the login credentials of CMC.

Message

An unsupported event occurred.

Details

The current software version cannot decode this event. You may need to review this event

 

using a tool which displays raw data such as Ipmitool with the -vvv option or Racadm with

 

the -E option.

Action

Upgrade the management software.

Message

A firmware or software incompatibility detected between iDRAC in slot <number> and CMC.

Details

FlexAddress is not implemented in one of the versions of firmware.

Action

Check the firmware versions of iDRAC and CMC. Update with the latest version.

Message

A firmware or software incompatibility detected between system BIOS in slot <number> and

 

CMC.

Details

FlexAddress is not implemented in one of the versions of firmware.

Action

Check the firmware versions of BIOS and CMC. Update with the latest version.

Message

A firmware or software incompatibility detected between CMC 1 and CMC 2.

Details

FlexAddress is not implemented in one of the versions of firmware. Please update the

 

firmware.

Action

Check firmware versions. Update CMC 1 and CMC 2 firmware to match.

SWC5001

Message

<name> upgrade failed.

 

 

Action

Reboot the system and attempt the upgrade again.

TMP0100

Message

The system board <name> temperature is less than the lower warning threshold.

 

LCD Message System board <name> temperature is outside of range.

105

Page 105
Image 105
Dell QHB owner manual Cmc