Error Code Message Information
| Details | The memory may not be operational. This an early indicator of a possible future |
|
| uncorrectable error. |
| Action | |
MEM1016 | Message | Memory device at location <location> is not installed correctly. |
| ||
| LCD Message Memory <location> is not installed correctly. Reinstall. | |
| Details | The memory may not be seated correctly, misconfigured, or has failed. Memory size is |
|
| reduced. |
| Action | Check the memory configuration. |
|
| see Getting Help. |
MEM1205 | Message | Memory mirror redundancy is lost. Check memory device at location(s) <location>. |
| ||
| LCD Message Memory mirror lost on <location>. Power cycle system. | |
| Details | The memory may not be seated correctly, misconfigured, or has failed. |
| Action | Check the memory configuration. |
|
| see Getting Help. |
MEM1206 | Message | Memory mirror redundancy is degraded. Check memory device at location <location>. |
| ||
| Details | The memory may not be seated correctly, misconfigured, or has failed. |
| Action | Check the memory configuration. |
|
| Getting Help. |
MEM1208 | Message | Memory spare redundancy is lost. Check memory device at location <location>. |
| ||
| LCD Message Memory spare lost on <location>. Power cycle system. | |
| Details | Memory sparing is no longer available. |
| Action | |
MEM1212 | Message | Memory redundancy is lost. |
| ||
| Details | The memory may not be seated correctly, misconfigured, or has failed. |
| Action | Review system logs for memory exceptions. reinstall memory at location <location> |
MEM1214 | Message | Memory redundancy is degraded. |
| ||
| Details | The memory may not be seated correctly, misconfigured, or has failed. |
| Action | Check the memory configuration. |
|
| Getting Help. |
MEM8000 | Message | Correctable memory error logging disabled for a memory device at location <location>. |
|