Error Code Message Information
| Details | The controller detected a drive removal. |
| Action | If unintended, verify drive installation. Remove and |
|
| issue persists, see Getting Help. |
PDR1001 | Message | Fault detected on drive <number> in disk drive bay <bay>. |
| ||
| LCD Message | Fault detected on drive <number> in disk drive bay <bay>. Check drive. |
| Details | The controller detected a failure on the disk and has taken the disk offline. |
| Action |
PDR1002
PDR1016
PDR1024
PST0128
PST0129
Message A predictive failure detected on drive <number> in disk drive bay<bay>.
Details The controller received a SMART error from the drive. The drive is operational but needs replacement.
Action The drive will need replacement at the next service window.
Message | Drive <number> is removed from disk drive bay <bay>. |
LCD Message | Drive <number> removed from disk drive bay <bay>. Check drive. |
Details | The controller detected that the drive was removed. |
Action | Verify drive installation. |
Message | Drive mismatch detected for drive <number> in disk drive bay <bay>. |
LCD Message | Drive mismatch detected for drive <number> in bay <bay>. Install correct drive type. |
Details | The installed disk does not meet the array requirements, for example a SATA disk may |
| not operate in an array containing SAS drives. |
Action | Verify that the disk meets the array requirements. |
Message | No memory is detected. |
LCD Message | No memory is detected. Inspect memory devices. |
Details | System BIOS was unable to detect memory in the system . |
Action | |
Message | Memory is detected, but is not configurable. |
LCD Message | Memory is detected, but is not configurable. Check memory devices. |
Details | System BIOS detected memory, but was unable to configure the memory for system |
| operation. |
Action | Compare system memory installation to supported system memory configurations. |