Dell QHB owner manual Service window

Models: QHB

1 121
Download 121 pages 28.19 Kb
Page 90
Image 90

Error Code Message Information

PCI3006

Message

Failed to get Link Tuning or FlexAddress data from iDRAC.

 

 

Details

Either the BIOS or BMC/iDRAC firmware is out of date and does not support FlexAddress.

 

Action

Update BIOS, and BMC/iDRAC firmware. If the issue persists, see Getting Help.

PCI3008

PCI3010

PCI3012

PCI3014

PDR0001

PDR0002

PDR0016

Message

A non-fatal PCIe error detected on a component at bus <bus>device<device>function

 

<func>.

Details

System performance may be degraded.

Action

Cycle input power, update component drivers, remove and reinstall the device at the next

 

service window.

Message

A non-fatal IO error detected on a component at bus <bus>device<device>function <func>.

Details

System performance may be degraded.

Action

Cycle input power, update component drivers, remove and reinstall the device at the next

 

service window.

Message

The QuickPath Interconnect (QPI) width degraded.

Details

System performance may be degraded. The bus is not operating at maximum speed or

 

width.

Action

Reset the system, if the problem persists reinstall processors.

Message

A non-fatal PCIe error detected on a component at slot <number>.

Details

System performance may be degraded.

Action

Cycle input power, update component drivers, remove and reinstall the device at the next

 

scheduled service time.

Message

 

Fault detected on drive <number>.

LCD Message

Fault detected on drive <number>. Check drive.

Details

 

The controller detected a failure on the disk and has taken the disk offline.

Action

 

Remove and re-seat the failed disk. If the issue persists, see Getting Help.

Message

A predictive failure detected on drive <number>.

Details

The controller received a SMART error from the drive. The drive is operational but needs

 

replacement.

Action

The drive will need replacement at the next service window.

Message

 

Drive <number> is removed.

LCD Message Drive <number> is removed. Check drive.

90

Page 90
Image 90
Dell QHB owner manual Service window