Battery
NVRAM backup battery | CR 2032 3.0 V Lithium coin cell |
Environmental
NOTE: For additional information about environmental measurements for specific system configurations, see dell.com/environmental_datasheets.
Storage Temperature | |
| temperature gradation of 20 °C per hour. |
Standard Operating | Continuous operation: 10 °C to 35 °C at 10% to 80% relative |
Temperature | humidity (RH), with 26 °C max dew point. |
| allowable dry bulb temperature at 1 °C per 300 m above |
| 900 m (1 °F per 550 ft). |
Expanded Operating |
|
Temperature |
|
| NOTE: When operating in the expanded temperature |
| range, system performance may be impacted. |
| NOTE: When operating in the expanded temperature |
| range, ambient temperature warnings may be reported |
| on the LCD and in the System Event Log. |
≤ 10% of annual operating hours | 5 °C to 40 °C at 5% to 85% RH with 26 °C dew point. |
| NOTE: Outside the standard operating temperature (10 |
| °C to 35 °C), the system can operate down to 5 °C or |
| up to 40 °C for a maximum of 10% of its annual |
| operating hours. |
| For temperatures between 35 °C and 40 °C, |
| maximum allowable dry bulb temperature by 1 °C per 175 |
| m above 950 m (1 °F per 319 ft). |
≤ 1% of annual operating hours | |
| NOTE: Outside the standard operating temperature (10 |
| °C to 35 °C), the system can operate down to |
| up to 45 °C for a maximum of 1% of its annual |
| operating hours. |
| For temperatures between 40 °C and 45 °C, |
| maximum allowable dry bulb temperature by 1 °C per 125 |
| m above 950 m (1 °F per 228 ft). |
Expanded Operating | |
Temperature |
|
Restrictions |
|