4.2 Programming Flowchart (continued)

Continued From Previous Page

TOT AL DECIMAL

 

TDEC

E

 

 

2345678

 

 

 

M

 

 

GAL

 

 

TOT AL

LIT

 

E

FT3

ToT DESC

DESCRIPT OR

M3

 

 

"blank"

M

 

 

(BBL, MCF)

 

 

 

 

SCALE

SEC

SEC

 

(ratemeter)

NNIN

r SCALE

E

HRS

 

 

(Days)

M

 

 

 

 

RA TE

 

234

E

DECIMAL

 

R DECLoC

LOCA TION

 

 

 

 

 

 

 

M

 

NORMALIZATION

 

 

E

 

 

nor

 

 

 

 

 

M

 

DELA Y

 

0.1

E

 

delay

 

0.1 to 99.9

 

 

M

 

 

 

 

OUT LOW

 

0000

E

(4mA)

 

oUT Lo

 

 

 

 

M

 

OUT HIGH

 

99999 E

(20mA)

 

oUT HI

 

 

 

M

 

PULSE

D 1

D 1

 

D 10

E

SCALER

D100

Pul scale

(divider)

oFF

 

M

 

 

 

 

PULSE

.5

.5

 

.25

E

 

 

WIDTH

.125

p uuidth

(seconds)

 

.0625

 

 

 

M

 

 

 

 

LOCK

 

0000

E

CODE

 

loc code

 

 

 

 

M

 

TURN LOCK

yes

yes

E

ON or OFF

no

loC UnIt

 

M

Press the key to step the totalizer decimal to the desired location. Press the E key to enter the displayed decimal location.

Press the M key to skip and keep the existing location

Press the key to step to the desired totalizer descriptor.

Press the E key to enter the displayed descriptor.

Press the M key to skip and keep the existing descriptor.

NOTE: When option "D" (rate per day) is ordered; selections are: GAL, BBL, MCF, M3, "blank"

Press the key to step to the desired scale setting.

Press the E key to enter the displayed scale setting.

Press the M key to skip and keep the existing setting.

NOTE: When option "D" (rate per day) is ordered; selections are: min, sec, days

Press the key to step the ratemeter decimal to the desired location. Press the E key to enter the displayed decimal location.

Press the M key to skip and keep the existing location

Press the key to increment each individual digit of the "nor" factor. Press the E key to enter the displayed value.

Press the M key to skip and keep the existing value.

Press the key to increment each individual digit of the delay.

Press the key to advance to the next digit.

Press the E key to enter the displayed value.

Press the M key to skip and keep the existing value.

Press the key to increment each individual digit of the out low setting (4mA value). This will only display on units with Analog Output.

Press the key to advance to the next digit.

Press the E key to enter the displayed value.

Press the M key to skip and keep the existing value.

Press the key to increment each individual digit of the out high setting (20mA value). This will only display on units with Analog Output.

Press the key to advance to the next digit.

Press the E key to enter the displayed value.

Press the M key to skip and keep the existing value.

Press the key to step to the desired pulse scale divider for the pulse output.

Press the E key to enter the displayed pulse scale divider. Press the M key to skip and keep the existing pulse scale value.

Press the key to step to the desired pulse width for the pulse output. Press the E key to enter the displayed pulse width.

Press the M key to skip and keep the existing pulse width.

This will not display if Pulse Out is turned OFF.

Press the key to increment each individual digit of the lock code.

Press the key to advance to the next digit.

Press the E key to enter the displayed value.

Press the M key to skip and keep the existing value.

Press the key to step to the desired lock setting.

Press the E key to enter the displayed lock setting.

Press the M key to skip and keep the existing setting.