Desa CD36TN-M Continued, parts list for venting kits and components, Vertical Venting

Models: CD36TN-M

1 44
Download 44 pages 7.76 Kb
Page 17
Image 17
Figure 23 - Vertical Venting

Venting Installation

instructions

Continued

Venting with Two 90° Elbows

Vertical (V)

Horizontal (H)

8' Min.

6' Max

9' Min.

8' Max

10' Min.

10' Max

12' Min.

14' Max

14' Min.

18' Max

40' Min.

20' Max

90° Elbow

Note: Install a

 

VR-58 vertical

 

restrictor ring

 

into inner pipe

 

section prior to

 

attaching vent

 

termination

 

cap.

Figure 23 - Vertical Venting

Configuration Using Two 90° Elbows

(Vertical Round High Wind Termination)

Note: Install a Firestop Plate FP-58 or a Firestop Thimble FTA-58 to maintain cleaance to combustible ceiling or insulating materials.

Note: Install a VR-58 Configuration Using Two 90° Elbows vertical restrictor ring (Vertical Round High Wind Termination) into inner pipe section prior to attaching vent

termination cap.

WS-5 8

Note: Install an OSR58-30 30° offset return with WS-58 wall strap supports as necessary to maintain 1" Clearance to all horizontal wood frame members.

Venting with Two 90°

Elbows

Vertical

Horizontal

(V1)

(H)

8' Min.

9' Max

9' Min.

11' Max

10' Min.

13' Max

12' Min.

17' Max

14' Min.

20' Max

Note: Install a VR-58 vertical restrictor ring into inner pipe section prior to attaching vent termination cap.

90°

Note: Vertical (V1)

Elbow

+ Vertical (V2) =

 

 

40' Max.

 

Horizontal Above

 

14' Vertical =

 

20' Max.

Vertical Venting

V = 40' Max.

Figure 25 - Vertical Venting

Configuration with No Horizontal Run (Vertical Round High Wind Termination)

parts list for venting kits and components

DESA (5"/8") Pipe & Vent Kits

Number Description

P58-6 6" Section Double Wall Pipe,

Galv.

P58-12 12" Section Double Wall Pipe,

Galv.

P58-24 24" Section Double Wall Pipe, Galv.

P58-36 36" Section Double Wall Pipe, Galv.

P58-48 48" Section Double Wall Pipe,

Galv.

PA58-712 Adjustable 7"-12" Section Double

Wall Pipe, Galv.

E58-45 45° Elbow, Galv.

E58-90 90° Elbow, Galv.

Figure 24 - Vertical Venting

Configuration Using Two 90° Elbows (Vertical Round High Wind Termination)

118531-01A

www.desatech.com

17

Page 17