Checking Gas Connections.
Tee Joint
Propane/LP From
External Regulator (11" W.C. to 14" W.C. Pressure)
Natural - From
Gas Meter (5.5" W.C. to 10.5" W.C. Pressure)

Fireplace

Installation

Continued

3.Attach flexible gas line from gas supply to control valve (see Figure 39).

4.Check all gas connections for leaks. See

Checking Gas Connections.

Figure 38 - Gas Connection WARNING: Use pipe joint sealant that is resistant to liquid petroleum (LP) gas.

We recommend that you install a sediment trap/ drip leg in supply line as shown in Figure 38. Lo- cate sediment trap/drip leg where it is within reach for cleaning. Install in piping system between fuel supply and fireplace. Locate sediment trap/drip leg where trapped matter is not likely to freeze. A sedi- ment trap traps moisture and contaminants. This keeps them from going into fireplace gas controls.

To Gas Supply (Natural)

To ExternalCONNECTING FIREPLACE TO GAS SUPPLYFigure 39 - Connecting Flexible Gas Line Regulator (Propane/LP)

Flexible Gas Line Do NOT Kink

Equipment Shutoff Valve

If sediment trap/drip leg is not installed or is in- stalled wrong, fireplace may not run properly.

CSA Design-Certified Equipment Shutoff Valve with 1/8" NPT Tap*

Approved

Flexible

Gas Line

3" Minimum to Millivolt ValveCHECKING GAS CONNECTIONS

Cap Pipe

Nipple

Sediment Trap/Drip Leg

Figure 38 - Gas Connection

*The CSA design-certified equipment shutoff valve may be supplied with the appliance or you can purchase it from your retailer.

CONNECTING FIREPLACE TO GAS SUPPLY

Installation Items Needed

• 5/16" hex socket wrench or nut-driver

• sealant (resistant to propane/LP gas, not provided)

1.Open lower louver door panel by gently pull- ing forward.

2.Route flexible gas line (provided by installer) from equipment shutoff valve to fireplace. Route flexible gas supply line through one of the access holes on side of fireplace.

Control Valve

Figure 39 - Connecting Flexible Gas Line

to Millivolt Valve

CHECKING GAS CONNECTIONS

Pressure Testing Gas Supply Piping System WARNING: Test all gas piping and connections, internal and external to unit, for leaks after installing or servicing. Correct all leaks at once.

Test Pressures In Excess Of 1/2 PSIG WARNING:Neveruseanopen flame to check for a leak. Apply noncorrosive leak detection fluid toalljoints.Bubblesformingshow a leak. Correct all leaks at once.

Pressure Testing Gas Supply Piping System

Test Pressures In Excess Of 1/2 PSIG

(3.5 kPa)

1. Disconnect fireplace and its individual equip- ment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig (3.5 kPa) will damage fireplace gas regulator.

2. Cap off open end of gas pipe where equipment shutoff valve was connected.

3. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas fireplace or opening main gas valve located on or near gas meter for natural gas fireplace or using compressed air.

24

www.desatech.com

118531-01A

Page 24
Image 24
Desa CD36TN-M Continued, Connecting Fireplace To Gas Supply, Checking Gas Connections, Installation Items Needed