Desa CD36TN-M Continued, Horizontal Termination, Configuration For Corner Installation

Models: CD36TN-M

1 44
Download 44 pages 7.76 Kb
Page 13
Image 13
Figure 14 - Horizontal Termination

Venting Installation

instructions

Continued

Horizontal Termination Configurations Figures 14 through 18 show different configura- tions and alternatives for venting with horizontal termination. Each figure includes a chart with critical minimum and maximum dimensions which MUST be met. IMPORTANT: Remember that a horizontal run of venting must have a 1/4" rise for every 12" of run toward the termination.

GROUND FLOOR INSTALLATION Recommended CHVK-58 Corner Horizontal Vent Kit:

Not to Exceed

(H) Limits

Square

Termination

H

TO

Wall

Firestop

90° Elbow

As Required Configuration For Corner Installation for (V), See Chart for Pipe Section Required

Installation using cabinet surrounds

Through the wall using square termination (up to 24" horizontal pipe)

Corner installation (Using one 6" vertical sec- tion, one 90° elbow and a maximum of 24" of horizontal pipe)

Horizontal

Straight/

 

Square

 

Adjustable

90°

Termination

Pipe 24" Max.

Elbow

 

 

 

Wall

Firestop

V

 

H

Corner Installation

Vertical (V)

Horizontal (H)

51" Min.

32 1/2" Max

Figure 14 - Horizontal Termination

Configuration For Corner Installation

Using One 90° Elbow

Required

Vertical (V)

Allowable

Vertical (V)

Vertical Pipe

Horizontal (H)

51"

6"

26" Max.

57 1/4" Min.

1'

30" Max.

69 1/4" Min.

2'

74" Max.

81 1/2" Min.

3'

98" Max.

94" Min.

4'

122" Max.

106" Min.

5'

146" Max.

159" Min.

9'

20' Max.

Figure 15 - Horizontal Termination

Configuration with Vertical Rise and One

90° Elbow

12"

Min.

Figure 16 - Square Termination

Clearance at Ground Floor Installation

118531-01A

www.desatech.com