Number

Venting Installation

instructions

 

Continued

Number

Description

CVVK-58

Ceiling Vertical Vent Kit

 

(Includes: 30° Offset Return, 7"-12"

 

Adjustable Pipe, Flue Restrictor,

 

Vertical High Wind Termination,

 

3' Pipe, 4' Pipe, Firestop Plate,

 

Firestop Thimble, Storm Collar,

 

Roof Flashing [0/12 - 6/12], 38

 

Screws)

CHVK-58

Corner Horizontal Vent Kit,

 

(Includes 90° Elbow, 7"-12"

 

Adjustable Pipe, Wall Firestop,

 

Horizontal Square Termination,

 

6" Pipe, 18 Screws)

HHTK-58

High Wind Round Horizontal

 

Termination Kit (Includes Round

 

Termination, Wall Firestop, 45°

 

Elbow)

HHT-58

High Wind Round Horizontal

 

Termination Kit, Galv.

HTS-58

Horizontal Square Termination,

 

Galv. HTKS-58 Horizontal Square

 

Termination Kit (Includes: Square

 

Termination, Wall Firestop, 45°

 

Elbow)

VT-58

Vertical Round Termination, Galv.

SC-58

Storm Collar, Galv.

WF-58

Wall Firestop, Galv.

RF-58-6

Roof Flashing - 0 to 6/12 Pitch,

 

Galv.

RF-58-12

Roof Flashing - 6/12 to 12/12

 

Pitch, Galv.

VR-58

Vertical Restrictor, Galv.

S-58

Vinyl Siding Standoff, Galv.

WS-58

Wall Strap

CS-58

Cathedral Ceiling Support

FP-58

Firestop Plate

SF-58

Stucco Flashing -

 

For use with HTS-58

RF-58

Flat Roof Flashing

Fireplace

Installation

ELECTRICAL SUPPLY CONNECTION

Description CAUTION: Disconnect the electrical power to the supply circuit before attempting to con- nect or service this appliance.

ELECTRICAL SUPPLY CONNECTION WARNING: This appliance, when installed must be electri- cally grounded in accordance with local code or in the ab- sence of local code, with the current National Electric Code, ANSI/NFPA 70, or the Canadian Electric Code, CSA C22.1.

A prewired junction box receptacle with strain relief is provided on the right side of the cabinet for hard wiring the unit to a 15 Amp, 120VAC, 60Hz grounded branch circuit. If the installation demands that the electrical supply be connected from the left side, the entire receptacle box can be relocated to the left side by following these instructions:

Note: If you do not need to relocate the junction box, to connect the electric supply follow steps 8 through 11 only:

1.Remove 2 screws and outer cover with strain relief bushing on right side of cabinet (see Figure 26).

2.Remove inner retaining screw on junction box mounting tab.

3.Slide junction box up until screw mounting tab is lined up to notch in outer cabinet.

J-Box Cover

J-Box

with Strain

Cover

Relief

J-Box Cover with

 

 

Strain Relief

Romex Cable

Figure 26 - Relocating Junction Box J-Box with

Receptacle Receptacle and Electrical Supply

Manual backgroundScrew/Tab Manual background Retainer

Figure 26 - Relocating Junction Box

Receptacle and Electrical Supply

Connection

18

www.desatech.com

118531-01A

Page 18
Image 18
Desa CD36TN-M installation manual Continued, Electrical Supply Connection, Number, Description, Relocating Junction Box