Gas Control Conversion

Conversion

Instructions

Continued

Gas Control Conversion

Convert the gas control by swapping out the valve regulator portion of the gas valve.

1.Using a Torx T20 or slotted screwdriver, re- move and discard the three mounting screws, pressure regulator tower, and diaphragm/ spring components (see Figure 58).

2.Insure that the rubber gasket is properly posi- tioned on the new pressure regulator assembly. Install LP pressure regulator assembly to valve using the new mounting screws supplied with the kit. Tighten screws securely (approxi- mately 25 in-lbs.) (see Figure 59).

3.Install the identification label enclosed with the gas valve regulator to the valve body, where it can easily be seen (see Figure 59).

Mounting

LO

Screws

HI

Pressure

Regulator

Tower

Diaphragm/

Spring

Components

 

O

 

 

FF

N

TO I

P

O

 

Figure 58 - Removing Mounting Screws,

Regulator, Tower, and Diaphragm/Spring

Components

Cleaning andGLASS DOORMounting

Screws

 

O

 

FF

N

P

O

TO I

Rubber

Gasket

Manual background Identification

Label

Figure 59 - Installing Pressure Regulator

Assembly

Cleaning and

Maintenance

Manual background WARNING: Turn off fireplace and let cool before cleaning.

Manual background CAUTION: You must keep control areas, burners and circulating air passageways of fireplace clean. Inspect these areas of fireplace before each use. Have fireplace inspected yearly by a qualified service person. Fireplace may need more frequent cleaning due to excessive lint from carpeting, bedding material, pet hair, etc.

GLASS DOOR

Manual background WARNING: Handle glass door panel with care. Do not strike, slam or otherwise abuse glass. Do not operate fireplace with the glass door unlatched, removed, cracked or broken.

118531-01A

www.desatech.com