unexpected disconnection or lens damage.

Maintenance and Troubleshooting

2.Locate and unplug the Motor Assembly Connector. Note the connector orientation for when you install the new lens.

3.Locate the six 9/64” Hex Mounting Screws (two each at 12 o'clock, 9 o'clock and 6 o'clock).

4.Remove the six Mounting Screws while supporting the Lens Assembly; Lens and Motor Assembly are now free.

5.Remove the Lens and Motor Assembly by pulling forward and to the left in order to clear the Projector chassis with the Motor Assembly.

6.Install New Lens Assembly: Repeat Steps 1 through 5 in reverse order.

Make sure to route the wire harness in its original position and away Caution from the moving lens stages and Motor Assembly, to prevent