Runco VX-6000D 1. Serial Commands continued, External Control, Parameter, Value, Description

Models: VX-6000D

1 112
Download 112 pages 43.78 Kb
Page 98
Image 98
Image Preset Commands

External Control

Table 6-1. Serial Commands (continued)

Command

Parameter

Value

Description

(min/max)

Stored?

 

 

 

 

 

 

 

Image Preset Commands

 

 

 

 

CUSTOM1

NA

YES

Loads “Custom” image preset

 

 

 

 

CUSTOM2

NA

YES

Loads “THX” (“Custom 2”) image preset

 

 

 

 

DAY

NA

YES

Loads “ISF Day” image preset

 

 

 

 

NIGHT

NA

YES

Loads “ISF Night” image preset

 

 

 

 

PRESET?

NA

NA

Returns currently-selected preset

 

 

 

(ISF Day, ISF Night, Custom or THX)

 

 

 

 

 

Input Position Commands

 

 

 

 

IHEIGHT

0/20

YES

Sets the value for input height

 

 

 

 

IHEIGHT?

NA

NA

Returns input height value

 

 

 

 

IHPOS

-50/50

YES

Sets a value for horizontal input position

 

 

 

 

IHPOS?

NA

NA

Returns input horizontal position value

 

 

 

 

IVPOS

-50/50

YES

Sets a value for vertical input position

 

 

 

 

IVPOS?

NA

NA

Returns input vertical position value

 

 

 

 

IWIDTH

0/50

YES

Sets the value for input width

 

 

 

 

IWIDTH?

NA

NA

Returns input horizontal width value

 

 

 

 

OVERSCAN

0/20

YES

Sets the overscan percentage

 

 

 

 

OVERSCAN?

NA

NA

Returns overscan percentage

 

 

 

 

OVERSCANMODE

0/1

YES

Sets the overscan mode (0=zoom;

 

 

 

1=crop)

 

 

 

 

OVERSCANMODE?

NA

NA

Returns the overscan mode (0=zoom;

 

 

 

1=crop)

 

 

 

 

 

Output Shift Commands

 

 

 

 

OHEIGHT

-50/50

YES

Sets the value for output height

 

 

 

 

OHEIGHT?

NA

NA

Returns output height value

 

 

 

 

OHPOS

-50/50

YES

Sets the value for output horizontal posi-

 

 

 

tion

 

 

 

 

OHPOS?

NA

NA

Returns output horizontal position value

 

 

 

 

OVPOS

-50/50

YES

Sets the value for output vertical position

 

 

 

 

OVPOS?

NA

NA

Returns output vertical position value

 

 

 

 

OWIDTH

-50/50

YES

Sets the value for output width

 

 

 

 

OWIDTH?

NA

NA

Returns output horizontal width value

 

 

 

 

82

Runco VX-6000d Installation/Operation Manual