Offset:

Next configurable function is offset and is indicated by the message ‘OFFSET’ followed by current offset value. To change the value of flashing digit press ^v key. To move the flashing digit, push <NXT> key. After programming the desired value of offset, push the "SETUP" key to get to the next function.

Tare:

Tare mode is indicated by the word 'TARE' followed by current Tare value. To change the value of flashing digit, press ^v key. To move the flashing digit, push <NXT> key. After programming the desired value of ‘TARE’ push ‘SETUP’ key (Minimum programmable tare is zero, maximum is equal to the scale value). This will take us back to the very beginning of SETUP mode with the display showing the message ‘SCALING’.

PROGRAM LIMITS:

Process Limits (1 thru 4):

If selection made from programming groups is for ‘PROG LT’ then the very first parameter programmed is process limit 1. This is indicated by the message ‘PrG LT1’ followed by pre-programmed value of the limit. Again, use <NXT> key to move flashing to the next digit and ^v key to increment/decrement the value of the flashing digit.

The following steps are very similar to the above (i.e. for Limits 2,3 and 4 and also if Limits 3 and 4 are setup as process limits) and allow you to enter process limits 2 through 4. However, limits 3 and 4 can be configured to work as rate and deviation limits, respectively. Therefore, after programming limit 2, the next step takes us into selection of limit 3 as rate or process limit.

Selection of Limit 3 as Process or Rate Limit:

This step comes after programming Limit 2 and is indicated by the message ‘LT3 RTE’ (if Limit 3 is setup as Rate limit) or ‘LT3 Pr’ (if Limit 3 is setup as Process limit). Alternate selection can be made by pushing ^v key. Push SETUP key after making the selection.

Programming Limit 3:

As Process Limit:

If Limit 3, in the above step, was configured as a Process limit, then the message displayed on entering this mode will be ‘PrG Lt3’. This will be followed by displaying of current value of Limit 3 . Use <NXT> key to move flashing to the next digit and ^v key to increment/decrement the value of the flashing digit.

As Rate Limit:

If Limit 3, in the above step, was configured as a Rate limit, then the message displayed on entering this mode will be ‘RATE Lt’. This will be followed by displaying of current value of Limit 3 . Use <NXT> key to move flashing to the next digit and ^v key to increment/decrement the value of the flashing digit.

6

Page 7
Image 7
Omega Engineering DP3600 user manual Program Limits

DP3600 specifications

Omega Engineering has long been a trusted name in the realm of industrial instrumentation, and their DP3600 series has set a high standard in differential pressure measurement. The DP3600 is celebrated for its robustness and versatility, making it a reliable choice for a variety of applications across industries such as HVAC, water treatment, and chemical processing.

One of the standout features of the DP3600 is its advanced microprocessor-based technology. This enables highly accurate measurements and ensures that the device can effectively manage multiple pressure inputs. The DP3600 operates on a wide measurement range, accommodating both high and low differential pressure readings with exceptional precision. It is designed to handle pressures from -500 to +500 inHg, making it suitable for even the most demanding environments.

The device is characterized by its user-friendly interface, which includes a clear digital display that shows real-time readings. This feature not only enhances usability but also ensures that operators can quickly interpret data without extensive training. Furthermore, the DP3600 offers a variety of output options including analog and digital signals, allowing for seamless integration with existing systems.

Durability is another key characteristic of the DP3600. Constructed to endure harsh conditions, it boasts an IP65 rating for dust and water resistance, making it suitable for use in outdoor and high-moisture environments. The unit is also designed for easy installation and maintenance, which helps reduce downtime and operational costs.

Moreover, the DP3600 series includes built-in safety features, such as over-range protection, ensuring that the device remains operational even in extreme conditions. With options for various materials and configurations, users can customize the DP3600 to better fit their application's requirements.

In summary, the Omega Engineering DP3600 series is an advanced differential pressure device that excels in accuracy, versatility, and durability. Its microprocessor-driven capabilities, broad measurement range, and user-friendly interface make it a valuable tool for professionals seeking reliable pressure measurement solutions in challenging environments. With these features, the DP3600 continues to be a preferred choice for industries requiring precise monitoring and control of differential pressure.