VI. COMMANDS FOR MEASUREMENT VALUES:
Command Receiving value
*01X01 (For all models): Reading value. After reading scale and offset.
Note: In order to have continuous update on reading. Customer
should send X01 command every time reading is requested.
Models(TC/RTD/ACV/ACC):
*01X02 Peak reading value.
*01X03 Valley reading.
Models(PR/ST/FP):
*01X03 Peak reading value.
*01X04 Valley reading.
*01V01 (For all models): String of values.
Received values are in decimal with decimal point and no sign for positive and minus sign
for negative.
Example : 00345.6 or -00345.6
If value is overflowed a “?” will be transmitted along with value (?-99999. or ?999999).
VII. COMMANDS FOR READING MODEL/INPUT TYPE:
Command Receiving value
*01U01 One byte for model number
VALUE MODEL
00 FP
01 PR
02 ST
03 TC
04 RTD
05 ACV
06 ACC
Page 16