6.3MODULE 3 - DISPLAY AND FRONT PANEL BUTTON PARAMETERS (3-dSP)

PARAMETER MENU

 

 

 

DISPLAY UPDATE TIME

dSP-t

«

0.5

1

2

seconds

ª

 

 

 

1

 

 

 

 

 

This parameter sets the display update time in seconds.FRONT PANEL DISPLAY SELECT ENABLE (SEL)
DISPLAY COLOR (BACKLIGHT UNIT ONLY)
COLOr

 

«

 

 

 

 

 

rEd 6rn

ª

 

 

 

 

rEd

 

 

Enter the desired display color, red or green. This parameter is active for backlight units only.

SEL

 

«

 

ª

 

 

 

yES NO

 

yES

 

 

The yES selection allows the SEL button to toggle through the enabled displays.FRONT PANEL RESET ENABLE (RST)

rSt

 

«

NO

LO

dSP

 

 

 

 

HI

HI-LO

 

ª

 

 

 

 

 

dSP

 

 

 

 

 

This selection allows the RST button to reset the selected value(s).ZERO DISPLAY WITH DISPLAY RESET

ZErO

«

 

ª

 

NO

yES NO

 

 

 

 

 

 

 

This parameter enables the RST button or user input to zero the input display value, causing the display reading to be offset.

Note: For this parameter to operate, the RST button or User Input being used must be set to dSP and the Input value must be displayed. If these conditions are not met, the display will not zero.

DISPLAY INTENSITY LEVEL (BACKLIGHT UNIT ONLY)

d-LEV

«

1 to 5

ª

 

 

 

5

 

Enter the desired Display Intensity Level (1-5). The display will actively dim or brighten as levels are changed. This parameter is active for backlight units only.

PROGRAMMING SECURITY CODE
CodE

 

«

000 to 999

ª

 

 

 

 

000

 

The Security Code determines the programming mode and the accessibility of programming parameters. This code can be used along with the Program Mode Lock-out (P-Loc) in the User Input Function parameter (Module 1).

Two programming modes are available. Full Programming mode allows all parameters to be viewed and modified. Quick Programming mode permits only the Setpoint values to be modified, but allows direct access to these values without having to enter Full Programming mode.

Programming a Security Code other than 0, requires this code to be entered at the CodE prompt in order to access Full Programming mode. Depending on the code value, Quick Programming may be accessible before the CodE prompt appears (see chart).

DISPLAY SCROLL ENABLE

ScroL

«

 

ª

 

NO

yES NO

 

 

 

 

 

 

 

The yES selection allows the display to automatically scroll through the enabled displays. The scroll rate is every 4 seconds. This parameter only appears when the MAX or MIN displays are enabled.

UNITS INDICATOR SELECTION
UNItS

 

«

 

 

 

ª

 

 

 

OFF

LISt

SEGS

 

OFF

 

 

 

 

This parameter activates the Units Indicator on the display. There are two methods of selecting the Indicator. List will present a group of Units preprogrammed into the meter. Segments allows the user to choose which of the segments should light.

USER INPUT

USER INPUT

SECURITY

MODE WHEN “SEL”

FULL PROGRAMMING

FUNCTION

STATE

CODE

BUTTON IS PRESSED

MODE ACCESS

 

 

 

 

 

 

 

 

 

0

Full Programming

Immediate Access

 

 

 

 

 

 

 

 

 

1-99

Quick Programming

After Quick Programming

not P-Loc

 

______

with correct code entry

 

 

 

at CodE prompt *

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100-999

CodE prompt

With correct code entry

 

 

 

 

 

 

at CodE prompt *

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

Programming Lock

No Access

 

 

 

 

 

 

P-Loc

 

Active

1-99

Quick Programming

No Access

 

 

 

 

 

 

 

100-999

CodE prompt

With correct code entry

 

 

 

 

 

 

at CodE prompt *

 

 

 

 

 

 

 

 

 

 

 

 

 

Not Active

0-999

Full Programming

Immediate Access

 

 

 

 

 

 

* Entering Code 222 allows access regardless of security code.