button or user input manual reset, serial reset command or meter power cycle. When the user input or RST button is activated (momentary action), the corresponding “on” output is reset immediately and remains off until the trigger point is crossed again. (Previously latched alarms will be off if power up Display Value is lower than setpoint value.)
|
| « |
|
|
| |
|
| NO | YES | |||
ª |
|
|
|
|
|
|
| YES |
|
|
|
This parameter enables the RST button or user input to reset the output when the display is reset.
Note: For this parameter to operate, the RST button or User Input being used must be set to dSP and the Input value must be displayed. If these conditions are not met, the output will not reset.
STANDBY OPERATION
| « |
|
|
| |
| NO | YES | |||
|
|
|
|
|
|
ª |
| NO |
|
|
|
When YES, the output is disabled (after a power up) until the trigger point is crossed. Once the output is on, the output operates normally per the Setpoint Action and Output Reset Action.
CHANGE DISPLAY COLOR w/OUTPUT STATE
| « |
|
|
| |
| NO | YES | |||
ª |
|
|
| ||
| NO | ||||
|
|
|
| ||
|
|
|
|
Setpoint Output Reset Actionswhen the output state changes. This parameter is only active for the backlight version.
6.5MODULE 5 - SERIAL SETUP PARAMETERS (5-SEr)
PARAMETER MENU
The Serial Setup Parameters are only active when the optional RS232 or RS485 serial communications module is installed in the meter. Refer to the