GENERAL METER SPECIFICATIONS

1. DISPLAY: 5 digit LCD 0.48" (12.2 mm) high digits DP63000A-I: Reflective LCD with full viewing angle

DP63000B-I: Transmissive LCD with selectable red or green LED backlight, viewing angle optimized. Display color change capability with output state when using an output module.

2. POWER: Input voltage range is +9 to +28 VDC with short circuit and input polarity protection. Must use a DP6-MLPS1 or a Class 2 or SELV rated power supply.

MODEL

DISPLAY COLOR

INPUT CURRENT

INPUT CURRENT

@ 9 VDC WITHOUT

@ 9 VDC WITH

NO.

 

DP6-RLY0

DP6-RLY0

 

 

 

 

 

 

DP63000A-I

---

10 mA

40 mA

DP63000B-I

Red (max intensity)

85 mA

115 mA

DP63000B-I

Green (max intensity)

95 mA

125 mA

3. INPUT RANGES: Jumper Selectable
D.C. Currents: 200 ∝A, 2 mA, 20 mA, or 200 mA
4. SIGNAL INPUTS:

INPUT

ACCURACY

INPUT

MAX

 

TEMP.

@23 °C, less

INPUT

RESOLUTION

RANGE

IMPEDANCE

COEFFICIENT

 

than 85% RH

 

SIGNAL

 

 

200 A

0.1% of span

1.111 K

15 mA

10 nA

70 ppm / °C

2 mA

0.1% of span

111

50 mA

.1 µA

70 ppm / °C

20 mA

0.1% of span

11

150 mA

1 µA

70 ppm / °C

200 mA

0.1% of span

1

500 mA

10 µA

70 ppm / °C

5.OVERRANGE RATINGS, PROTECTION & INDICATION:

9 to 28 VDC power circuit is not isolated from the signal circuit. Input Overrange Indication: “OLOL”.

Input Underrange Indication: “ULUL”.Display Overrange/Underrange Indication: .....”/“-.....6.DISPLAY RESPONSE TIME: 500 msec min.7.NORMAL MODE REJECTION: 60 dB 50/60 Hz

8.USER INPUT (USR): Programmable input. Connect terminal to common (USR COMM) to activate function. Internal 10KΩ pull-up resistor to +9 to 28 VDC.

Threshold Levels: VIL = 1.0 V max; VIH = 2.4 V min; VMAX = 28 VDC
Response Time: 5 msec typ.; 50 msec debounce (activation and release)

9.MEMORY: Nonvolatile E2PROM memory retains all programming parameters and max/min values when power is removed.

10. ENVIRONMENTAL CONDITIONS:Operating Temperature Range for DP63000A-I:-35 to 75°C

Operating Temperature Range for DP63000B-I depends on display color and intensity level as per below:

 

INTENSITY LEVEL

TEMPERATURE

Red Display

1 & 2

-35 to 75°C

 

3

-35 to 70°C

 

4

-35 to 60°C

 

5

-35 to 50°C

Green Display

1 & 2

-35 to 75°C

 

3

-35 to 65°C

 

4

-35 to 50°C

 

5

-35 to 35°C

Storage Temperature: -35 to 85°C

Operating and Storage Humidity: 0 to 85% max. relative humidity (non- condensing)

Vibration According to IEC 68-2-6: 5 to 500 Hz, in X, Y, Z direction for 1.5 hours, 5 g’s.

Shock According to IEC 68-2-27: Operational 30 g, 11 msec in 3 directions
Altitude: Up to 2000 meters
11.CONNECTIONS: Wire clamping screw terminals Wire Strip Length: 0.3" (7.5 mm)
Wire Gage: 30-14 AWG copper wire
Torque: 5 inch-lbs (0.565 N-m) max.

12.CONSTRUCTION: This unit is rated for NEMA 4X/IP65 requirements for indoor use. Installation Category I, Pollution Degree 2. High impact plastic case with clear viewing window. Panel gasket and mounting clip included.

13.CERTIFICATIONS AND COMPLIANCES:SAFETY

UL Recognized Component, File #E313607, UL61010A-1, CSA22.2 No. 61010-1 Recognized to U.S. and Canadian requirements under the Component Recognition Program of Underwriters Laboratories, Inc.

UL Listed, File # E313547, UL508, CSA C22.2 No. 14-M95 LISTED by Und. Lab. Inc. to U.S. and Canadian safety standards

IEC 61010-1, EN 61010-1: Safety requirements for electrical equipment for measurement, control, and laboratory use, Part 1.

IP65 Enclosure rating (Face only), IEC 529
Type 4X Indoor Enclosure rating (Face only), UL50
ELECTROMAGNETIC COMPATIBILITY

Emissions and Immunity to EN 61326: Electrical Equipment for Measurement, Control and Laboratory use.

Immunity to Industrial Locations:

 

Electrostatic discharge

EN 61000-4-2

Criterion A

 

 

4 kV contact discharge

 

 

8 kV air discharge
Electromagnetic RF fields

EN 61000-4-3

Criterion A

 

 

10 V/m
Fast transients (burst)

EN 61000-4-4

Criterion A

 

 

2 kV power

 

 

1 kV signal
Surge

EN 61000-4-5

Criterion A

 

 

1 kV L-L,

 

 

2 kV L&N-E power

RF conducted interference

EN 61000-4-6

Criterion A

 

 

3 V/rms

Power frequency magnetic fields EN 61000-4-8

Criterion A

Emissions:

 

30 A/m

 

 

Emissions

EN 55011

Class A
Notes:
1.Criterion A: Normal operation within specified limits.
14.WEIGHT: 3.2 oz (100 g)

PART NUMBER INFORMATION

DESCRIPTION

PART NUMBER

 

 

DC Current Meter with reflective display

DP63000A-I

 

 

DC Current Meter with backlight display

DP63000B-I

 

 

Single Relay Output Card

DP6-RLY0

 

 

Dual Sinking Open Collector Output card

DP6-SNK0

RS485 Serial Communications Card

DP6-COM1

 

 

RS232 Serial Communications Card

DP6-COM2

 

 

Micro-Line Power Supply, 85 to 250 VAC

DP6-MLPS1

 

 

RS232 Programming Cable (DB9-RJ11)

DP6-232-CABLE

 

 

RS485 Programming Cable (DB9-RJ11)

DP6-485-CABLE

 

 

PC Configuration Software for Windows 98, ME, 2000, XP *

DP6-SOFT

4