5.CERTIFICATIONS AND COMPLIANCES:

SAFETY

UL Recognized Component, File #E313607, UL61010A-1, CSA C22.2 No. 1010-1

Recognized to U.S. and Canadian requirements under the Component Recognition Program of Underwriters Laboratories, Inc.

UL Listed, File #E313547, UL508, CSA C22.2 No. 14-M95 LISTED by Und. Lab. Inc. to U.S. and Canadian safety standards

Type 4X Indoor Enclosure rating (Face only), UL50

IEC 61010-1, EN 61010-1: Safety requirements for electrical equipment for measurement, control, and laboratory use, Part 1.

IP65 Enclosure rating (Face only), IEC 529

ELECTROMAGNETIC COMPATIBILITY EMC specifications determined by the model.

6.ENVIRONMENTAL CONDITIONS:

Operating Temperature Range: Determined by the model

Storage Temperature Range: -40 to 60°C

Operating and Storage Humidity: 0 to 85% max. RH (non-condensing)

Altitude: Up to 2000 meters

7.MOUNTING REQUIREMENTS: Max. panel thickness is 0.375" (9.5 mm)

Min. panel thickness for NEMA 4/IP65 sealing is 0.060" (1.52 mm)

8.MODULE INSTALLATION:

24-pin shrouded connector on LDP63100 engages connector on input module upon installation. Shroud ensures proper alignment by providing a lead-in for the module connector.

9.CONNECTIONS: Wiring connections are made to the LDP63100 terminal block and input module via high compression cage-clamp terminal blocks. Input Module Wiring: Instructions are provided in the included bulletin. LDP63100 Terminal Block Wiring:

Wire Strip Length: 0.3" (7.5 mm)

Wire Gage: 30-12 AWG copper wire

Maximum Torque: 5-7 inch-lbs (0.58-0.81 N-m)

CAUTION: DISCONNECT ALL POWER BEFORE

INSTALLING OR REMOVING MODULE

10.CONSTRUCTION: Aluminum front panel, enclosure, and rear cover with textured black polyurethane paint for scratch and corrosion resistance protection. Sealed front panel meets NEMA 4X/IP65 specifications for indoor use when properly installed. Installation Category II, Pollution Degree

2.Panel gasket and keps nuts included.

11.WEIGHT: 5 lbs (2.25 kg) (less module)

OPTIONAL PLUG-IN CARDS AND ACCESSORIES

WARNING: Disconnect all power to the unit before installing Plug-in cards.

Adding Option Cards

The LDP63100 series meters can be fitted with up to three optional plug-in cards. The details for each plug-in card can be reviewed in the specification section of the included manual. Only one card from each function type can be installed at one time. The function types include Setpoint Alarms (LDP6-CDS), Communications (LDP6-CDC), and Analog Output (LDP6-CDL). The plug-in cards can be installed initially or at a later date.

SETPOINT ALARMS PLUG-IN CARDS (LDP6-CDS)

The LDP63100 series has 4 available setpoint alarm output plug-in cards. Only one of these cards can be installed at a time. (Logic state of the outputs can be reversed in the programming.) These plug-in cards include:

LDP6-CDS10 - Dual Relay, FORM-C, Normally open & closed LDP6-CDS20 - Quad Relay, FORM-A, Normally open only LDP6-CDS30 - Isolated quad sinking NPN open collector LDP6-CDS40 - Isolated quad sourcing PNP open collector

ANALOG OUTPUT PLUG-IN CARD (LDP6-CDL)

Either a 0(4)-20 mA or 0-10 V retransmitted linear DC output is available from the analog output plug-in card. The programmable output low and high scaling can be based on various display values. Reverse slopes output is possible by reversing the scaling point positions.

LDP6-CDL10 - Retransmitted Analog Output Card

COMMUNICATION PLUG-IN CARDS (LDP6-CDC)

A variety of communication protocols are available for the LDP63100 series. Only one of these cards can be installed at a time. When programming the unit via Crimson, the RS232 or RS485 Cards must be used.

LDP6-CDC10 - RS485 Serial (Terminal) LDP6-CDC1C - RS485 Serial (Connector)

LDP6-CDC20

- RS232 Serial (Terminal)

LDP6-CDC2C - RS232 Serial (Connector)

LDP6-CDC40

- Modbus (Terminal)

LDP6-CDC4C - Modbus (Connector)

PROGRAMMING SOFTWARE

DP6-SOFT is a Windows® based program that allows configuration of the LDP63100 meter from a PC. This software offers standard drop-down menu commands, that make it easy to program the LDP63100 meter. The program can then be saved in a PC file for future use. A serial plug-in card is required to program the meter using the software.