3.0 WIRING AND PROGRAMMING THE DISPLAY

3.0 WIRING AND PROGRAMMING THE DISPLAY

Once assembled, the LDP63100 has all the same functions and capabilities of our DP63500, DP63600, and DP63700 Series Intelligent Panel Meters. Therefore, you will find the appropriate meter information packed with the LDP63100. Simply follow the instructions to wire and program the display for your application.

Note: Both the LDP63100 and the input module require power. It is recommended to connect the primary AC power to the LDP63100 terminal block, then jumper to the input module.

LDP63100 PROGRAMMING

The unit is a large display, designed to be remotely mounted. Therefore, the unit does not have a programming keypad. Unit programming must be accomplished by one of the following three methods:

Optional Programming Remote (LDP6-PGM)

This optional programming remote plugs into the LDP63100 through an RJ12 connector and a 10 foot cable. The buttons on the programming box function the same as the DP63500, DP63600, and DP63700 meters. Simply program the LDP63100 exactly as the meter instructions indicate. The programming box can be left connected to the LDP63100 for future programming changes or can be disconnected and used to program additional LDP63100 units.

Rear Terminal Block

External normally open switches can be wired via the terminal block to allow unit programming. A minimum of 3 switches would be required. Each external switch must be wired between the key and the common terminal.

LDP63100 TERMINAL BLOCK

RJ12 CONNECTOR ON BOTTOM OF UNIT

7