3.4.3Management Support
3.4.3.1VLAN
The NMM Management Processor can independently transmit and receive Management Data with an IEEE 802.1Q tag. To enable and configure this feature, type 9 from the Management Options screen to access the Other Networking Features screen.
Other Networking Features Screen | iConverter, Serial Agent |
1: Enable/Disable DHCP Client | Disabled |
2: Enable/Disable Keep Alive Trap | Disabled |
3: Keep Alive Trap interval | 10 |
4: Serial Baud Rate | 57600 bps |
5: Enable/Disable Remote OAM | Enable |
6: Enable/Disable IP Protocol | Enable |
7: Enable/Disable VLAN Support | Disabled |
8: VLAN ID | 2 |
9: VLAN Priority | 7 |
Enter Choice, Management Options Screen(0), (H)elp, E(x)it >
To configure the VLAN management ID, select option 8. To configure the priority setting for the VLAN management channel, select option 9. To enable or disable VLAN management support, select option 7.
Once VLAN support is enabled, IP management support will only be accessible using the configured
VLAN ID.
To save the new values, select 0 and press <ENTER> to return to the Management Options screen, then select 6 and press <ENTER> to Save Preference Changes.
3.4.3.2Remote OAM
Remote OAM (Operations, Administration and Maintenance) allows the NMM to support
Remote OAM is enabled by default. For
To save the new values, select 0 and press <ENTER> to return to the Management Options screen, then select 6 and press <ENTER> to Save Preference Changes.
3.4.4Enabling/Disabling
The
When the
When the
Page 16