Chimney Installation:

Chimney Installation:

Do not connect this unit to a chimney flue serving another appliance. Do not connect to any air distribution duct or system.

The SCAN A10 stove is listed for installation as a vertically top or rear vented stove using a listed class A (UL103HT) for Canada (CAN/ULC-S629) factory built chimney exiting through the ceiling/attic/roof. The inside diameter of the chimney, connector pipe must not be smaller than 6” (152 cm) diameter. Single wall 24 gauge MSG (0.58 – 0.71 mm) and adapter must not be smaller than 6” (152 mm), may be used in the room where the stove is installed, follow the chimney manufacturer’s instruction for installation of chimney and chimney adapter. In Canada, where passage through wall, or partition of combustible construction is desired, the installation shall conform to CAN/CSA B365.

Factory Built Chimney

When a metal prefabricated chimney is used, the manufacturer’s installation instructions must be followed. You must also purchase (from the same manufacturer) and install the ceiling support package or wall pass-through and “T” section package, fire stops (where needed), insulation shield, roof flashing, chimney cap, etc. Maintain proper clearance to the structure as recommended by the manufacturer. The chimney must be the required height above the roof or other obstructions for safety and proper draft operation. See page 15 for Chimney Height Requirements.

Masonry Chimney

Ensure that a masonry chimney meets the minimum standards of the National Fire Protection Association (NFPA) by having it inspected by a professional. Make sure there are no cracks, loose mortar or other signs of deterioration and blockage. Have the chimney cleaned before the stove is installed and operated. When connecting the stove through a combustible wall to a masonry chimney, special methods are needed. Refer to Combustible Wall Chimney Connector Pass- Throughs on page 14.

Top vent installation

Mounting of the flue collar for top vent. Turn the flue collar around and fix the brackets under the top plate.

Tighten the two screws with the delivered hexagon spanner (tighten well)

Required installation components:

Chimney cap

Insulated chimney

Storm collar

Roof flashing

Ceiling support box or joist shield/fire stop spacer

Chimney connector pipe

Chimney connector adapter