Chimney Installation:
Do not connect this unit to a chimney flue serving another appliance. Do not connect to any air distribution duct or system.
The SCAN A10 stove is listed for installation as a vertically top or rear vented stove using a listed class A (UL103HT) for Canada
Factory Built Chimney
When a metal prefabricated chimney is used, the manufacturer’s installation instructions must be followed. You must also purchase (from the same manufacturer) and install the ceiling support package or wall
Masonry Chimney
Ensure that a masonry chimney meets the minimum standards of the National Fire Protection Association (NFPA) by having it inspected by a professional. Make sure there are no cracks, loose mortar or other signs of deterioration and blockage. Have the chimney cleaned before the stove is installed and operated. When connecting the stove through a combustible wall to a masonry chimney, special methods are needed. Refer to Combustible Wall Chimney Connector Pass- Throughs on page 14.
Top vent installation
Mounting of the flue collar for top vent. Turn the flue collar around and fix the brackets under the top plate.
Tighten the two screws with the delivered hexagon spanner (tighten well)
Required installation components:
•Chimney cap
•Insulated chimney
•Storm collar
•Roof flashing
•Ceiling support box or joist shield/fire stop spacer
•Chimney connector pipe
•Chimney connector adapter
12