6. TROUBLESHOOTING

Smoke:

-Insufficient chimney draught!

-Check if the chimney has the right dimension.

-Check if the smoke pipe or chimney is blocked.

-Check if the chimney has the right height compared to the surroundings.

-Wood with excessive moisture content.

The wood burns too fast:

-Are the air valves adjusted correctly according to the instructions?

-Is the smoke deflector plate placed correctly?

Soiled glass:

-Is the combustion air valve adjusted according to the instructions?

-Is the wood dry?

Polluted chimney:

-Incorrect combustion

-Is the wood dry?

The shaking grate is stuck:

-Check if a piece of wood, a pin or the like is stuck.

-Is the bar placed/mounted correctly?

The stove’s surface turns gray:

- Over heating - please refer to the maintenance section: Cleaning of Stove.

The stove does not heat:

- Use of moist wood. Extra energy is used to dry the wood.