Omnitron Systems Technology A10 manual Rear Vent Installation

Models: A10

1 25
Download 25 pages 38.61 Kb
Page 14
Image 14
Rear Vent Installation

Rear Vent Installation

For venting into a masonry or a back standing steel chimney through the top vent the top horizontal portion of a single wall connector pipe can be located not closer than 18” below a combustible ceiling.

From the factory the stove is prepared for top mounting of the flue collar, but all SCAN stoves have an optional flue outlet, therefore the flue collar can be fitted either on the top or at the rear as required.

Mounting the flue collar for rear outlet:

1.Remove the part of the back plate inside the groove for access to the rear outlet.

2.Remove the part of the inner back plate inside the groove for access to the rear outlet.

3.Remove the inner cover plate (cooking ring) by means of the hexagon spanner.

4.The flue collar is fitted from the outside into the discharge hole of the firebox in such a way that the bracket is located on the inside.

5.Place the cooking ring on top so that this is level with the top plate.

Rear venting into a masonry or steel chimney through a thimble or other vent configuration than descript here must follow local codes or NFPA 211 or CAN/CSA-B365 guidelines and methods.

Required installation components:

Chimney cap

Insulated chimney

Tee section

Tee support bracket

Chimney connector pipe

Wall thimble

Wall strap