Omron D4BL Approved Standard Ratings, Characteristics, TÜV EN60947-5-1, CCC GB14048.5, A300, A-69

Models: D4BL

1 16
Download 16 pages 778 b
Page 3
Image 3
■Approved Standard Ratings

Approved Standard Ratings

TÜV (EN60947-5-1), CCC (GB14048.5)

Item

 

Standard model

Indicator model

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Utilization category

 

AC-15

AC-15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rated operating current (Ie)

3 A

6 A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rated operating voltage (Ue)

250 V

115 V

 

 

 

 

 

Use a 10-A fuse type gI or gG that conforms to IEC60269 as a short-circuit protection device.

 

 

 

UL/CSA (UL508, CSA C22.2 No. 14)

 

 

 

 

A300

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rated voltage

Carry current

 

Current

 

 

Volt-amperes

 

 

 

 

 

 

 

 

 

 

 

 

 

Make

 

 

Break

Make

 

Break

 

 

 

 

 

 

 

 

 

 

120 VAC

10 A

 

60 A

 

6 A

 

7,200 VA

 

720 VA

 

 

 

 

 

 

 

 

 

 

240 VAC

 

 

30 A

 

3 A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: The UL/CSA approved rating for products with indicators (-A) is 6 A/115 VAC.

Characteristics

Degree of protection (See note 2.)

IP67 (EN60947-5-1) (This applies for the Switch only. The degree of protection for the key hole is

 

IP00.)

 

 

 

Durability (See note 3.)

Mechanical: 1,000,000 operations min.

 

Electrical: 500,000 operations min. (10-A resistive load at 250 VAC)

 

 

 

Operating speed

0.05 to 0.5 m/s

 

 

 

Operating frequency

30 operations/min max.

 

 

 

Rated frequency

50/60 Hz

 

 

 

 

Contact gap

2 x 2 mm min.

 

 

 

 

Operating characteristics

Direct opening force:

19.61 N min. (EN60947-5-1) (See note 4.)

 

Direct opening travel: 20 mm min. (EN60947-5-1) (See note 4.)

 

All stroke:

23 mm min.

 

 

Lock holding strength

700 N min. (GS-ET-19)

 

 

Insulation resistance

100 Mmin. (at 500 VDC)

 

 

 

Rated insulation voltage (Ui)

300 V (EN60947-5-1)

 

Conventional enclosed thermal current

10 A (EN60947-5-1)

 

(Ithe)

 

 

Dielectric strength (Uimp)

Impulse dielectric strength (Uimp) 4 kV (EN60947-5-1) between terminals of different polarity, between

 

each terminal and ground, and between each terminal and non-current-carrying metal part;

 

2.5 kV between solenoid and ground (EN60947-5-1)

 

 

 

Conditional short-circuit current

100 A (EN60947-5-1)

 

 

 

 

Pollution degree (operating

3 (EN60947-5-1)

 

environment)

 

 

 

 

Protection against electric shock

Class I (with ground terminal)

 

 

Switching overvoltage

1,500 V max. (EN60947-5-1)

 

 

Contact resistance

50 mmax. (initial value)

 

 

Vibration resistance

Malfunction: 10 to 55 Hz, 0.35-mm single amplitude

 

 

Shock resistance

Destruction: 1,000 m/s2 min. (IEC68-2-27)

 

Malfunction: 300 m/s2 min. (IEC68-2-27)

Ambient temperature

Operating: –10°C to 55°C (with no icing)

 

 

 

Ambient humidity

Operating: 95% max.

 

 

 

 

Weight

Approx. 800 g

 

 

 

 

Note: 1. The above values are initial values.

2.The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing properties are sufficient for the operating conditions and environment beforehand. Although the switch box is protected from dust, oil or water penetration, do not use the D4BL in places where dust, oil, water, or chemicals may enter through the key hole on the head, otherwise Switch damage or malfunctioning may occur.

3.The durability is for an ambient temperature of 5°C to 35°C and an ambient humidity of 40% to 70%.

4.These figures are minimum requirements for safe operation.

Safety Door Switches D4BL

Guard Lock Safety-door Switch D4BL

A-69

Page 3